Download Print this page

Bonnet Neve COLISEUM 4 ECO User Instructions page 15

Hide thumbs Also See for COLISEUM 4 ECO:

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 14
Make sure that the system power supply voltage corresponds to the values appearing on the rating plate of the equip-
ment. Consider also that the maximum allowable power voltage variation is +/-6%.
IMPORTANT: THE EQUIPMENT MUST BE PROPERLY EARTHED. The manufacturer assumes no responsibility
for any damage resulting from non-observance of this safety principle. If the cabinet must be installed far
from electric power source, make certain that the connection complies with the standards in force.
THE MANUFACTURER DISCLAIMS ALL RESPONSIBILITY FOR ANY PERSONAL INJURY OR PROPERTY DAMAGE ARI-
SING FROM INCORRECT INSTALLATION.
6. TECHNICAL SPECIFICATIONS
The built-in electrical installation is composed of control devices lodged in the upper part of the refrigerated cabinet.
The technical details, which are also reported on the rating plate, inside the display case (see fig. 8 on page 5) are
shown in table III, page 5.
The sound level generated by the equipment is below 70 dB(A). This refrigerated cabinet generates no harm-
ful vibrations.
WE HEREBY DECLARE THAT THE DISPLAY CASE AT ISSUE COMPLIES WITH D.L. (DECREE LAW) DATED 25/JAN/1992
N° 108 AS EXECUTING EEC DIRECTIVE 89/109 ON MATERIALS AND OBJECTS FIT FOR CONTACT WITH EDIBLES.
WE HEREBY DECLARE THAT THE SHOWCASE AT ISSUE IS ADEQUATE FOR THE PRESERVATION OF FRO-
ZEN PRODUCTS IN COMPLIANCE WITH LAW No. 283 DATED 30/APRIL/42 AND SUBSEQUENT
AMENDMENTS, AND
26/MARCH/81 No. 85.
7. LOADING PRODUCTS
Once the technicians have completed cabinet installation, switch it on through the wall cut-out switch. The cabinet will
then start its cooling cycle. Allow about two hours before loading products, which must already be at their preserva-
tion temperature. THE DISPLAY CASE IS FACTORY-REGULATED FOR THE ANTICIPATED PERFORMANCE.
When loading products make certain that:
• they are similar in size and type;
• the shelf load limit (160 kg/sq.m for shelves) is not exceeded;
• products do not cover the slots that ensure the correct circulation of cool air (see fig. 9, page 6).
8. USE
The showcase was designed and manufactured exclusively for the display of ice-creams and frozen food (class L). Its
function is preserving food temperature, not lowering it. Therefore, when introduced, THE FOODSTUFFS
MUST BE AT THEIR CONSERVATION TEMPERATURE. Do not load foods that have undergone heating. Use
padded gloves when handling ice-creams and frozen food.
OPEN DOOR LOCKING SYSTEM
For loading an cleaning purpose the door can be loked in open position by shifting the locking system as
shown by the arrow in the figure 16, page 7.
TENSION ADJUSTMENT OF DOOR CLOSING SPRING
If the tension of the return sprng has to be increased, it is necessary to carry out the steps in figure 17, page 7.
DECREE LAW OF 29/JAN/81 PUBLISHED IN THE OFFICIAL GAZETTE dated