How to use the hood

A
Fig. 3
Control Panel
A – Motor switch-off key
B – Hood switch-on key and speed selection 1-2-
3-1-2…
C – 1
speed indicator (LED)
st
D - 2
speed and saturation of the anti-fat filter
nd
indicator (LED)
E – 3
speed and saturation of the anti-fat filter
rd
indicator (LED)
F – Intensive speed indicator
G – Intensive speed key (LED). Intensive speed
lasts 5 minutes. If the hood is working when
intensive speed is started, it will return to the
previously set speed once the time has passed
(5 minutes). If the hood is off when intensive
speed is started, it switches off automatically at
the time limit (5 minutes). It is, for example,
opportune to use intensive speed to evacuate
odours after finishing cooking.
H – Illumination OFF key.
I – Illumination ON key.
If the hood or the commands are not working,
disconnect the electricity supply for at least 5 minutes
and start the apparatus again.
Control device of the saturation
of the grease and active carbon
filters.
The aspiration hood is equipped with a device that
signals when the grease or active carbon filter
(recirculation with carbon filter version) needs
cleaning.
The hood is delivered from the factory without the
carbon filter and therefore the LED that signals filter
saturation is inactive.
All manuals and user guides at all-guides.com
B C D E
F
G
H
Activate the LED as indicated below if the hood
has to be used with the carbon filter:
Press keys B and G simultaneously for three
seconds. The D anti-fat filter LED lights up and then
the E carbon filter LED as well. At this point the
LED that signals the saturation of the active carbon
filter has been activated.
Deactivation. Press keys B and G simultaneously
for three seconds until the E carbon filter LED
switches off.
Grease filter LED (D)
The D LED begins to flash when the anti-fat filter
needs to be washed.
The anti-fat filter must be changed after about 40
hours of use. Follow the instructions for changing
the anti-fat filter.
The active carbon filter LED (E)
The E LED begins to flash when the active carbon
filter must be changed.
The anti-fat filter must be changed after about 160
hours of use. Follow the instructions for changing
the active carbon filter.
Restoring the saturation indicator
After having carried out maintenance on the filter,
keep key A held for 3 seconds until the LED of the
anti-fat filter D or the LED of the carbon filter E
stops flashing
Attention! Restoring the saturation indicators
MUST be carried out with the hood set in Stand-
by and therefore without disconnecting the hood
from the power supply.
Correct ventilation
A vacuum must be created in the kitchen for the
correct functioning of the hood.
It is important to keep the kitchen windows closed
and have a window open in an adjacent room.
Important
If the hood is used together, for example, with an
open fireplace that takes air from inside the house,
a draught might occur that could bring fumes into
the room. Open a window.
This does not concern the active carbon filter version.
Do not use the hood at an excessive speed. The
lower speeds are sufficient for normal cooking.
I