Installation
Mounting the hood
Adjust the height of the structure of the telescopic
support previously:
· Fix the two sections of the telescopic support
structure with a total of 8 “a” screws (Fig. 8).
Calculate the height of the 290 mm hood and
the minimum distance from the cooking top
(see fig. 7).
Before proceeding, arrange the hood as
follows:
Aspiration version:
Fix a 150-diameter evacuation tube sufficiently
long so as to reach the connection ring when the
hood has been installed.
Recirculation version:
Fix the deflector on the side through the holes on
the upper section of the telescopic support
structure (Fig. 9).
ATTENTION!
The holes used must be at right angles with
respect to the upper fixing points “c” on the
flue assembly (Fig. 8).
· Fix the deflector with the bracket and the 4
supplied screws (Fig.9).
· Fix the connection ring on the deflector from
below (bayonet plug – turn clockwise and fix
with a screw). (Fig.10).
· Fix a 150 mm diameter tube sufficiently long as
to reach the connection ring when the hood is
installed (Fig. 10).
The following instruction concern both
functions:
· Make a hole in the ceiling as indicated on the
holing template.
· Fix the support structure to the ceiling with 4
screws and the “b” dowel (Fig.8).
The sides with the fixing points of the external flue
correspond with the “c” fixing points of the
support structure (Fig.8).
The hood is equipped with fixing dowels
suitable for most ceilings.
It is however necessary to consult a qualified
technician to ascertain the suitability of the
materials according to the type of ceiling.