INCIDENT N°14
State of LEDS and various devices
Normal
INCIDENT N°15
Etat des LEDS et divers organes
Normal
INCIDENT N°15
State of LEDS and various devices
Normal
INCIDENT N°16
Etat des LEDS et divers organes
Normal
DEFECT : THE ARC FLICKERS
Probable cause
ð control PCB
ð connection B71 and B61
ð filter PCB thyristor diode
DEFAUT : EVANOUISSEMENT NON REGLABLE
Cause probable
ð P4 potentiomètre
d'évanouissement
ð carte cycle
DEFECT : SLOPE-OUT NOT ADJUSTABLE
Probable cause
ð P4 slope-out potentiometer
ð cycle PCB
DEFAUT : POSTGAZ NON REGLABLE
Cause probable
ð P5 potentiomètre de postgaz
ð carte cycle
Control and remedies
ð check between terminals 4 and
9 of B71, 6 and 9 of B72, 7
and 8 of B71 that U is identical
in welding
ð check with ohmmeter
ð if no breakdown has been
element previously detected ,
check that no has been
disconnected
Contrôles et remèdes
ð vérifier + 1 2 V fils 301 et 300
de P3, variation 0 + 1 2 entre
308 et 300 de P3 vérifier B12
entre 11 et 9, une variation de
0 à 12 V
ð changer si aucune panne
détectée précédemment
Control and remedies
ð check + 12 wires 301 and
300 of P3 variation 0 + 12
between 308 and 300 of P3
check B12 between 11 and 9,
a variation from 0 to 12 V
ð change if no breakdown has
been previously determined
Contrôles et remèdes
ð + 12 V fils 309 et 300 aux
bornes de P9 et variation de 0
à + 1 2 V entre 300 et 307 de
P9, vérifier variation 0 à + 1 2
V aux bornes 8 et 2 de B12
ð changer, si aucune panne
détectée précédemment