INSTALLATION DETAIL
6 1/2" min. (16 cm)
HINGE PIN
CLEARANCE FOR
DOOR REMOVAL
13" min. (33 cm)
DOOR CLEARANCE
3/4" (19 mm) CONDUIT FOR 120/230 VAC
ICC-PL
®
ICC-800-SAT PEDESTAL
FINISH GRADE
3/4" (19 mm) CONDUIT FOR 120/230 VAC
3/4" (19 mm) CONDUIT FOR GCBL WIRING (IF REQUIRED FOR IMMS)
ICC-PLASTIC-PED
®
ICC CONTROLLER
PLASTIC CABINET
1 1/4", 1 1/2" OR 2" (32, 40 OR 50 mm)
3/4" (19 mm) CONDUIT FOR 120/230 VAC
CONDUIT FOR VALVE WIRES
ICC CONTROLLER
METAL CABINET
ICC PEDESTAL
CONCRETE
FINISH GRADE
(SLOPE TO DRAIN)
1 1/4", 11/2" or 2" (32, 40 or 50 mm)
3/4" (19 mm) CONDUIT FOR 120/230 VAC
CONDUIT FOR VALVE WIRES
ICC Controller
13" min. (33 cm)
DOOR CLEARANCE
MODULE AND WIRE
ACCESS PANEL
1 1/4", 1 1/2" OR 2" (32, 40 OR 50 mm)
CONDUIT FOR VALVE WIRES
®
ICC-M
1 1/4", 1 1/2" OR 2" (32, 40 OR 50 mm)
CONDUIT FOR VALVE WIRES
ICC-PED
®
ICC CONTROLLER
METAL CABINET
CONCRETE
(SLOPE TO DRAIN)