Tabs: F10 - Boundless ADDS 3153 LF ASCII Manual To Operations

Display terminal
Table of Contents

Advertisement

Set Control: [Temporary, Permanent]
Temporary – Set Control commands do not replace the values stored in NVRAM. Only the working setup
parameters are modified.
Permanent – The Set Control commands update both the working setup parameters as well as the NV setup
parameters.
Status Line: [Off, Indicator, Host-Write, Both]
Specify the way in which the status line is to be used: for host messages [host-write], as a cursor position
indicator [indicator], for [both] or off.
Char Set: [Multinational, National]
Select whether the character set used is from the 7-bit national chart or the 8-bit multinational chart. The
default is the 8-bit multinational character set except when the emulation is VT100.
WP-Graphics: [Off, On]
Selects whether Word Perfect Graphics commands are processed or ignored.

Tabs: F10

Auto Init Tabs: [On, Off]
When on, tab settings will always be defaulted at power up.
Default Tabs: This action field sets tabs at every eighth column starting at column 9.
When the cursor is placed in the Tab Map, the keys below will appear in the Choices field:
<Space> – clear the current tab setting.
<Shift> <Backspace> – clear all tab settings.
<T or t> – set a tab at the current location.
< ↑ → ↓ ← > – move cursor on the Tab map or back to a Parameter field above the map.
Tab: [Field, Column]
Field – On a formatted page, the tab stops are defined by the field attribute characters displayed on the
screen.
Column – The column tab stops are used while ignoring the field attribute characters.
Setup
37