Installation Instructions - Zehnder Rittling Centair CMEV.4e Installation Instructions Manual

Mechanical extract ventilation (mev) system
Hide thumbs Also See for Centair CMEV.4e:
Table of Contents

Advertisement

1.1.11
If the supply cord is damaged, it must be replaced by a special cord / assembly available from the
manufacturer or its service agent. The replacement must be carried out by a qualified electrician in
accordance with IEE or local regulations.
1.1.12
Observe appropriate safety precautions if working on steps or ladders. Wear eye protection when
breaking out wall or window materials, etc.
1.1.13
To disassemble the unit, disconnect from mains supply and use a screwdriver to segregate the
electronic components and motor from the plastic housing. Dispose items in accordance with WEEE.
1.1.14
WEEE Statement
This product may not be treated as household waste. Instead it should be handed to an
appropriate collection point for the recycling of electrical and Electronic equipment.
For more detailed information about the recycling of this product, please contact your
local council office or your household waste disposal service.
1.2
Physical Specification
2.0

Installation Instructions

2.1
General Preparation
2.1.1
The CMEV.4e range of units are supplied with 5 x 125mm ducting spigots for connection of ducts to the unit for
installation and 2 x blanking caps to close or block off unused spigots. One inlet spigot is located under the base
of the unit and is supplied blanked off. For installations requiring fifth inlet port, proceed to cut out the
spigot blank and connect duct. (See Figure 1).
2.1.2
125mm duct should be used to provide the best performance levels required for compliance with building
regulations. The CMEV.4e range has been tested with both 125mm and 100mm round ducting. Note; Reducing
ductwork to 100mm will increase system resistance and affect overall specific fan power ratings. Technical
Services can be contacted on +44 (0) 1276 408402 should you have any questions in respect of this.
2.1.3
Installation of the unit should be in accordance with the current editions of Building Regulations and BS7671: IEE
Wiring Regulations.
2.1.4
The design, material specification and installation must only be carried out by 'competent persons'. Electrical
installation must be carried out by a qualified Electrician.
2.2
Positioning / Application
2.2.1
The unit can be installed in any plane and should be sited in a service cupboard, on a wall or ceiling or in a loft
space (See Figure 2).
2.2.2
The unit must be securely mounted at each corner using either single or slotted fixing holes provided (See Figure 3).
Note; Fixing points have been designed to hold screws, for ease, when positioning/mounting the product to a
surface.
Front
Side
3