Relay Settings Advanced

Here you can change various settings that influence the operation of the individual relays.
Items you can change:
Relay Reset Data Tag [1-2]
Waker Duration
Mantracourt Electronics Limited T24-RM1 User Manual
15
Enter a Data Tag that on receipt will reset the latched relay. Enter zero to
disable this feature.
Enter a time in milliseconds for this module to attempt to wake acquisition
modules when first powered up. The default is 12000 milliseconds (12
seconds).
When this is non zero the acquisition modules will be kept awake while this
module has power applied. The acquisition modules should have a Sleep Delay
set so that after the relay module has been powered down the acquisition
modules then return to sleep.
Enter zero to disable this feature.