Audio Alarm - Kodak X-Omat M43 Diagnostics Manual

Processors
Hide thumbs Also See for X-Omat M43:
Table of Contents

Advertisement

SITE SPECIFICATIONS
The table below summarizes the Service Routines available and the necessary position for all the
SWITCHES on the 100 CIRCUIT BOARD.
Table 1 SWITCH Positions for Service Routines
Service Routine
No Service Routines Running
REPLENISHMENT PUMP
WASH RECIRCULATION PUMP and WASH
DIVERTER SOLENOID L3 of the DIVERTER
VALVE ASSEMBLY (M43 & M43A only)
DEVELOPER HEATER
WATER INPUT SOLENOID
DEVELOPER COOLING SOLENOID L2 of
the DIVERTER VALVE ASSEMBLY (M43 &
M43A only)
WASH RECIRCULATION PUMP and
DEVELOPER COOLING SOLENOID L2 of
the DIVERTER VALVE ASSEMBLY (M43 &
M43A only)
STATUS INDICATORS
FILM SENSORS
DEVELOPER TEMPERATURE DISPLAY
(M43 & M43A only)

AUDIO ALARM

Figure 1 DIP SWITCH Settings
P103
P108
6
P104
P103
SWITCH
SWITCH
1
2
Off
Off
On
On
On
Off
On
On
On
Off
On
On
On
Off
On
Off
On
On
On
On
On
Off
P104
P105
100 BD.
SWITCH
SWITCH
SWITCH
3
4
Off
Off
Off
Off
On
Off
On
Off
Off
On
Off
On
Off
Off
On
On
On
On
Off
Off
On
Off
P105
R42
DIP SWITCHES
shown in the
OFF position
H130_0146HCA
H130_0146HA
October 1994 – 981093
5
Off
Off
Off
Off
Off
Off
On
Off
Off
On
On

Advertisement

Table of Contents
loading

This manual is also suitable for:

X-omat m43aX-omat clinic 1

Table of Contents