Recovery Pump RP Lite Model 760R User Manual page 42

Massage system
Table of Contents

Advertisement

RP Lite
Model 760R
®
Conducted
RF
3 Vrms
IEC
150 kHz to 80 MHz
61000-4-6
Radiated RF
3 V/m
IEC
80 MHz to 2.5 GHz
61000-4-3
NOTE 1: At 80 MHz and 800 MHz, the higher frequency range applies.
NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and
reflection from structures, objects and people.
a Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile
radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To
assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be
considered. If the measured field strength in the location in which the Model 760R is used exceeds the applicable RF
compliance level above, the Model 760R should be observed to verify normal operation. If abnormal performance is
observed, additional measures may be necessary, such as re-orienting or relocating the Model 760R.
b Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.
Recommended Separation Distances between Portable and Mobile RF Communication
The Model 760R is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled.
The customer or the user of the Model 760R can help prevent electromagnetic interference by maintaining a minimum
distance between portable and mobile RF communications equipment (transmitters) and the Model 760R as recommended
below, according to the maximum output power of the communications equipment.
Rated Maximum Output
Power of Transmitter
W
0.01
0.1
1
10
100
For transmitters rated at a maximum output power not listed above, the recommended separation distance d in meters (m)
can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power
rating of the transmitter in watts (W) according to the transmitter manufacturer.
NOTE 1: At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and
reflection from structures, objects and people.
38
RP Sports
3 Vrms
3 V/m
Equipment and the Model 760R
Separation Distance according to Frequency of Transmitter
150 kHz to 80 MHz
80 MHz to 800 MHz
P
d = 1.2
0.12
0.38
1.2
3.8
12
P
d = 1.2
P
d = 1.2
80 MHz to 800 MHz
P
d = 2.3
800 MHz to 2.5 GHz
Where P is the maximum output power rating of the
transmitter in watts (W) according to the transmitter
manufacturer and d is the recommended separation
distance in meters (m).
Field strengths from fixed RF transmitters, as
determined by an electromagnetic site survey,
be less than the compliance level in each frequency
range.
b
Interference may occur in the vicinity of equipment
marked with the following symbol:
m
P
d = 1.2
0.12
0.38
1.2
3.8
12
User Manual
should
a
800 MHz to 2.5 GHz
P
d = 2.3
0.23
0.73
2.3
7.3
23
L98107R0-G