RF emissions
CISPR 11
Harmonic emissions
IEC 61000-3-2
Voltage fluctuations/
flicker emissions
IEC 61000-3-3
Model 760R - Electromagnetic Immunity – Manufacturer's Declaration
The Model 760R is intended for use in the electromagnetic environment specified below. The
customer or the user of the Model 760R should assure that it is used in such an environment.
Immunity Test
Electrostatic discharge
(ESD)
IEC 61000-4-2
Electrical fast transient/
burst
IEC 61000-4-4
Surge
IEC 61000-4-5
Voltage dips, short
interruptions and voltage
variations on power supply
input lines
IEC 61000-4-11
Power frequency
(50/60 Hz) magnetic field
IEC 61000-4-8
NOTE: U
is the a.c. mains voltage prior to application of the test level.
T
Model 760R - Electromagnetic Immunity - Manufacturer's Declaration
The Model 760R is intended for use in the electromagnetic environment specified below. The
customer or the user of the Model 760R should assure that it is used in such an environment.
Immunity
IEC 60601 Test
Test
Level
L98107R0-G
Class B
The Model 760R is suitable for use in all establishments, including
Complies
domestic establishments and those directly connected to the public
low voltage power supply network that supplies buildings used for
domestic purposes.
Complies
IEC 60601 Test
Level
±6 kV contact
Complies
±8 kV air
±2 kV for power
Complies
supply lines
±1 kV line to line
Complies
>95% dip in UT for
0.5 cycle
60% dip in UT for
5 cycles
Complies
30% dip in UT for
25 cycles
>95% dip in UT for
5 cycles
3 A/m
Complies
Compliance
Level
Compliance
Electromagnetic Environment -
Level
Mains power quality should be that of a
typical domestic or hospital
environment.
Mains power quality should be that of a
typical domestic or hospital
environment.
Mains power quality should be that of a
typical domestic or hospital
environment.
Power frequency magnetic fields should
be at levels characteristic of a typical
location in a typical domestic l or
hospital environment.
Electromagnetic Environment - Guidance
Portable and mobile RF communications equipment
should be used no closer to any part of the Model
760R, including cables, than the recommended
separation distance calculated from the equation
applicable to the frequency of the transmitter.
Recommended separation distance
Guidance
37