Hydraulic elevator for disabled people

Advertisement

Available languages

Available languages

ENGLISH
 
Installation instructions _______________________________________________
Bring the elevator to the pool
Level it and regulate it if necessary by the set screws attached on the anchoring structure nº 1 and nº 3.
Regulate, if necessary, the swivel located inside the vessel nº 2, leaving it against the wall of the pool.
Attention: do not loosen the set screws placed in sets nº 5 and nº 6, as this would put out of order
the whole cylinder assembly, damaging its joints.
Once the lift is on place, proceed to mark the fastening holes in the pavement (three holes drilled in the
anchorage disc)
Remove the lift and drill the floor
Once it is drilled, put the lift and the fastening stoppers, tightening them until they are secure and well-
tightened.
Look over the vertical level of the cylinder and proceed with the corrections, if necessary, with the swivel and
the set screws.
Review the regulation elements so that there are no loose elements.
Place the water inlet to the elevator in order to feed the circuit. The lift is equipped with a fast outlet made for
an easy connection to the water network. The emptying of the cylinder is done in the same pool through the
lower tube of the three-way valve.
After connecting the water outlet, proceed to start making it work repeatedly until the air gets out of the
cylinder. You will notice it when the cylinder goes up slowly without any fluctuations.
 