CONTENTS
1. GENERAL .......................................................................... 1
2. OPTIONS ........................................................................... 2
3. INSTALLATION ............................................................... 3
4. TESTING ............................................................................ 5
5. CONTROL PORT OPERATION ...................................... 7
7. MAINTENANCE ............................................................. 16
8. DEPLOYMENT GUIDELINES ...................................... 16
IDSL OCU-R ......................................................... 1
IDSL/DDS Circuit Diagram ................................. 2
Circuit Card Pin Assignments ............................... 4
IDSL/DDS Trouble Codes .................................... 6
Local Loop ............................................................ 7
Customer Loop ...................................................... 7
RS-232 (DB-9) Pin Assignments .......................... 7
Main Menu Screen ................................................ 9
Figure 10. Terminal Modes Menu Screen .............................. 9
Figure 11. System Status Screen .......................................... 10
Figure 12. IDSL Detailed Status Screen ............................... 10
Figure 13. Loopbacks Screen ................................................ 11
Figure 14. Performance Monitoring Screen ......................... 11
Screen .................................................................. 12
Screen .................................................................. 12
Screen .................................................................. 13
Screen .................................................................. 13
Figure 19. Event Log Screen ................................................ 14
Figure 20. Set Circuit ID Screen ........................................... 14
Figure 21. Set Date and Time Screen ................................... 15
Figure 22. ADTRAN Information Screen ............................ 15
Options .................................................................. 2
Compliance Codes ................................................ 4
Table 4.
Wiring Connections .............................................. 4
Table 5.
LED Indicators ...................................................... 5
Alternating Loopback Sequences ......................... 5
Latching Loopback Sequences ............................. 5
Definition of Screen Abbreviations ...................... 8
61220010L2-5C
T200 IDSL OCU-R
Remote Termination Unit

Installation and Maintenance

61220010L2-5, Issue 3
Trademarks: Any brand names and product names included in this document are
trademarks, registered trademarks, or trade names of their respective holders.
IDSL
OCU-R
1220010
SYNC
CRC
NO
DSU
AP
NTWK
LBK
CUST
LBK
LBK
O
F
F
O
F
F
Frame IQ
LISTED
CUSTOM
TELECOM
E190349
Figure 1. IDSL OCU-R

1. GENERAL

Revision History
Description
Section 61220010L2-5C
Issue 3, April 2001
CLEI # NCT1TX2B _ _
SW 2
SC
64
56
19.2
SW 4
9.6
4.8
2.4
SW
56
-10
dB
QM
SW 1
EC
LL
EN
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the T200 IDSL and is the answer not in the manual?

Questions and answers

Summary of Contents for ADTRAN T200 IDSL

  • Page 1: Table Of Contents

    Screen ... 13 Figure 19. Event Log Screen ... 14 Figure 20. Set Circuit ID Screen ... 14 Figure 21. Set Date and Time Screen ... 15 Figure 22. ADTRAN Information Screen ... 15 TABLES Table 1. Options ... 2 Table 2.
  • Page 2: Options

    Channel Bank 2-Wire Loop T-Carrier IDSL OCU-R T/R Pair Figure 2. IDSL/DDS Circuit Diagram Features 2. OPTIONS Customer Premises 4-Wire Customer Interface DSU/CSU Customer Interface Transmit Line Build Out 61220010L2-5, Issue 3 Table 1. Options , 2 . , 6 . , 8 .
  • Page 3: Installation

    Quality Monitor (QM) Error Correction (EC) Latching Loopback Enabled (LLEN) False Loopback Immunity Latching Loopback Protected Loopback 61220010L2-5C Table 2. Protected Loopback Mode Requirement T1E1.2/99-007R1 (Latching Sequence Function Exit data Idle - 11111110 protocol Clear existing Transition in loopbacks progress (TIP) X0111010 Identify device Loopback select...
  • Page 4: Figure 3. Circuit Card Pin Assignments

    Wiring Span Power Applications Local Power Applications Table 3. Compliance Codes i t a l l a i t a -48 Vdc RET -48 Vdc PWR Network Figure 3. Circuit Card Pin Assignments Table 4. Wiring Connections – – 61220010L2-5, Issue 3 IDSL OCU-R Frame Ground (TT)
  • Page 5: Testing

    LED Indication Table 5. LED Indication i r c i t p e t a a c i s e t a c i s e t a c i s e t a c i s e t e r r , t n a c i s e t...
  • Page 6: Figure 4. Idsl/Dds Trouble Codes

    IDSL/DDS Trouble Code Figure 4. IDSL/DDS Trouble Codes Loopback LED Operation ADTRAN U-BR1TE Bidirectional Loopback ADTRAN U-BR1TE Bidirectional loopback Figure 5. ADTRAN U-BR1TE Bidirectional Remote End Initiated LBK Tests 61220010L2-5, Issue 3 IDSL OCU-R Test Loopback 61220010L2-5C...
  • Page 7: Control Port Operation

    ASC 9Eh U-BR1TE Figure 6. IDSL/DDS Remote End Initiated Loopback, Local Loop ASC 9Eh U-BR1TE Figure 7. IDSL/DDS Remote End Initiated Loopback, Customer Loop 5. CONTROL PORT OPERATION TXD (Transmit Data) RXD (Receive Data) SGN (Signal Ground) Figure 8. RS-232 (DB-9) Cable Side Pin Assignments 61220010L2-5C 4-Wire...
  • Page 8: Table 8. Definition Of Screen Abbreviations

    Table 8. Definition of Screen Abbreviations 61220010L2-5, Issue 3 61220010L2-5C...
  • Page 9: Figure 9. Main Menu Screen

    * Faster of the two modes * You cannot print screens to a log file * Highlighting is enabled * Recommended for daily operation Figure 10. Terminal Modes Menu Screen 61220010L2-5C Adtran IDSL Main Menu Status Loopbacks Performance Monitoring Event Log Set Circuit ID...
  • Page 10: Figure 11. System Status Screen

    CIRCUIT ID:IDSL Test Unit Channel Bank ____________ UBR1TE NETWORK| |____________| CIRCUIT ID:IDSL Test Unit Figure 12. IDSL Detailed Status Screen System Status Screen |<000------------------000>| MARGIN -----> 20| Legend Detailed Status Selection: Figure 11. System Status Screen IDSL INTERFACE DATA UBR1TE OCU-R (CUST) (NET)
  • Page 11: Latching Loopback Timeout

    Latching Loopback Timeout CIRCUIT ID:IDSL Test Unit Channel Bank ____________ UBR1TE NETWORK| |____________| CIRCUIT ID:IDSL Test Unit Figure 14. Performance Monitoring Screen 61220010L2-5C LOOPBACKS |<------------------------>| |____________| Loop UBR1TE Toward Customer—< Not Available > Loop OCU-R Toward Network Loop OCU-R Toward Customer Deactivate Loopback Loopback Timeout: Disabled...
  • Page 12: Figure 15. U-Br1Te 15-Minute Performance Monitoring Screen

    Clearing PM and Event Log Registers CIRCUIT ID:IDSL Test Unit UBR1TE IDSL INTERFACE -ES-UAS--CRC- 000 000 00000 02:30 000 000 00000 02:15 000 003 00000 02:00 000 000 00000 01:45 000 000 00000 01:30 000 000 00000 01:15 000 000 00000 01:00 000 000 00000 00:45...
  • Page 13: Figure 17. Frame Relay 15-Minute Performance Monitoring Screen

    CIRCUIT ID:IDSL Test Unit IDSL INTERFACE -INV--FECN--BECN---LMI--%UT 00000 00000 00000 00000 000 02:30 00000 00000 00000 00000 000 02:15 00000 00000 00000 00000 000 02:00 00000 00000 00000 00000 000 01:45 00000 00000 00000 00000 000 01:30 00000 00000 00000 00000 000 01:15 00000 00000 00000 00000 000 01:00 00000 00000 00000 00000 000 00:45 00000 00000 00000 00000 000...
  • Page 14: Figure 19. Event Log Screen

    CIRCUIT ID:IDSL Test Unit EVENT FIRST DDS SYNC LOSS 07/24/00 11:10:04 DDS LOOP OPEN 07/24/00 11:10:04 OCU-R MARGIN -------- -------- DSL SYNC LOSS 07/24/00 11:10:04 OCU-R POWER 07/24/00 11:10:01 LAST LOG RESET 01/03/98 03:33:20 CIRCUIT ID:IDSL Test Unit EVENT LOG LAST 07/24/00 20:45:03 07/24/00 20:45:03...
  • Page 15: Figure 21. Set Date And Time Screen

    901 Explorer Boulevard, Huntsville, AL 35806-2807 -----------Manufacturing Information----------- Unit PART # ----- ---------- OCU-R 1220010L2 Figure 22. ADTRAN Information Screen 61220010L2-5C Set System Date and Time New Date = (MM/DD/YY) New Time = (HH/MM/SS) Figure 21. Set Date and Time Screen...
  • Page 16: Remote Provisioning And Diagnostics

    6. REMOTE PROVISIONING AND DIAGNOSTICS Control Protocol Provisioning and Status Flashes 7. MAINTENANCE 8. DEPLOYMENT GUIDELINES 9. WARRANTY AND CUSTOMER SERVICE ADTRAN Carrier Networks Equipment Warranty, Repair, and Return Policy and Procedure, 61220010L2-5, Issue 3 61220010L2-5C...
  • Page 17: Adtran Sales

    ADTRAN Sales Pricing/Availability (800) 827-0807 ADTRAN Technical Support Pre-sales Applications/Post-sales Technical Assistance (800) 726-8663 ADTRAN Repair/CAPS Return for Repair/Upgrade (256) 963-8722 Repair and Return Address ADTRAN, Inc. CAPS 901 Explorer Boulevard Huntsville, Alabama 35806-2807 61220010L2-5C 61220010L2-5, Issue 3...