ENGLISH
• Unscrew the hose from the appliance.
Keep a rag nearby because some water
may flow.
• Clean the filter in the valve with a stiff
brush or with the piece of cloth.
35°
45°
• Turn on the water tap.
Emergency drain
If the appliance cannot drain the water, carry
out the same procedure, described in
'Cleaning the drain pump' paragraph. If
necessary, clean the pump.
When you drain the water with the
emergency drain procedure, you must
activate the drain system again:
1. Put 2 litres of water in the main wash
compartment of the detergent dispenser
drawer.

Troubleshooting

Warning! Refer to Safety
chapters.
Introduction
The appliance does not start or it stops during operation.
First try to find a solution to the problem (refer to the table). If the problem persists, contact
the Authorised Service Centre.
Warning! Deactivate the appliance before carrying out any check.
In case of major problems, the acoustic signals operate, the display shows an alarm
code and the Start/Pause
- The mains supply is unstable. Wait until the mains supply is stable.
• Screw the hose
back to the
appliance turning it
to the left or the
right to suit the
installation. Tight
the locknut
correctly to prevent
water leaks.
button may flash continuously:
2. Start the programme to drain the water.
Frost precautions
If the appliance is installed in an area where
the temperature can reach values around 0°
C or drop below, remove the remaining
water from the inlet hose and the drain
pump.
1. Disconnect the mains plug from the
mains socket.
2. Close the water tap.
3. Put the two ends of the inlet hose in a
container and let the water flow out of
the hose.
4. Empty the drain pump. Refer to the
emergency drain procedure.
5. When the drain pump is empty, install
the inlet hose again.
Warning! Make sure that the
temperature is higher than 0 °C
before you use the appliance
again.
The manufacturer is not
responsible for damages caused
by low temperatures.