Hatco Glo-Ray Infra-Black GRAIH Series Installation And Operating Manual page 11

Strip heaters
Table of Contents

Advertisement

Available languages

Available languages

English
Minimum Clearance Requirements
Models
GRAIH and GRAIHL
with TCBI
(102 mm)
GRAIH and GRAIHL
with RMB
(102 mm)
GRAIH-xxD and
GRAIHL-xxD with TCBI
(203 mm)
GRAIH-xxD and
GRAIHL-xxD with RMB
(203 mm)
Pass-Through Shelf
C
Counter
Minimum Clearance Requirements
■ Must be a pass-through application, not allowed with back
wall installation.
Maximum Overshelf Clearance Requirements
Units should be mounted at a maximum distance of 10"
(254 mm) from the front of an overshelf.
Overshelf
10"
(254 mm)
Counter
Maximum Overshelf Clearance Requirements
Form No. GRAIHM-0920
A
B
C
4"
1"
(25 mm)
4"
3"
0"
(76 mm)
(0 mm)
8"
1"
(25 mm)
8"
3"
0"
(76 mm)
(0 mm)
B
A
Recommended Mounting Heights
6"
(152 mm)
9-1/2"
(241 mm)
Recommended Element Height
for GRAIH-xx and GRAIHL-xx models
15"
(381 mm)
19"
(483 mm)
Recommended Element Height for
GRAIH-xxD and GRAIHL-xxD models with a 3" (76 mm) spacer
18"
(457 mm)
22"
(559 mm)
Recommended Element Height for
GRAIH-xxD and GRAIHL-xxD models with a 6" (152 mm) spacer
11
INSTALLATION
4"–10"
(102–254 mm)
8"–14"
(203–356 mm)
8"–14"
(203–356 mm)

Advertisement

Table of Contents
loading

Table of Contents