Bomag BW 154 AP-4 Manual page 48

Electrics-training
Table of Contents

Advertisement

2020
The required control power cannot be
transmitted to the proportional
solenoid.
2021
Supply voltage Ub is applied to the
proportional valve output, even
though the output is not switched.
2024
Supply voltage Ub is applied to the
proportional valve output, even
though the output is not switched.
2025
Output to proportional valve shorted
to ground.
2026
Fault current regulator
2022
Output to proportional valve shorted
to ground.
2029
Initialization error output
2023
The required control power cannot be
transmitted to the proportional
solenoid.
X35:47
Valve coil defective
Line breakage in current path
X35:47
Current path has connection to +Ub (15 or 30)
X35:47
Current path has connection to +Ub (15 or 30)
X35:47
Short circuit to ground (31) in the current path
Excessive current in current path
X35:47
Line breakage in current path
Excessive current in current path
Software parameter fault, software update may be required.
X35:47
Short circuit to ground (31) in the current path
Excessive current in current path
System
Software parameter fault, software update may be required.
ESX hardware defect, hardware replacement may be necessa
X35:47
Valve coil defective
Line breakage in current path
2
5
5
2
2
2
2
2