Programming Mode:

Many features of the readout can be customized, plus additional tools can be
configured using the programming menu. Consult the Complete User Guide at
www.proscale.com
saving customized settings.
Before making changes, open the readout case and verify the programming
menu is accessible. The jumper to the left of the battery has three pins. Ensure
pins 1 and 2 are connected with a shunt before proceeding. (After making
changes, you can move the shunt to pins 2 and 3 to prevent further
programming changes.)
To start the programming menu, turn on the readout.
1. Press and hold the UNITS key.
2. Quickly press and release DATUM key. You will see PG on, then Pr1.
3. Release the UNITS key.
4. After a moment, the value for Pr1 will display.
Change the parameter value using the PLUS or MINUS keys.
Default the parameter value using the DATUM key.
Advance to next parameter by pressing the UNITS key.
Exit programming menu following steps 1-3 above (OR wait 30
seconds). Note: Changes made are immediately active.
Parameter
number
Pr1
Pr2
Pr3
Pr4
Pr5
Pr6
Pr7
Pr11
Pr12
Manual Part # 800-1403-001 Revision 06-01-2020
for more information about accessing, changing, and
What it does
Sets the value that is displayed when
DATUM key is pressed.
0 = numbers increase when encoder
moves right
1 = numbers decrease when encoder
moves right
0 = PLUS, MINUS, and DATUM keys
are operative
1 = These keys are locked out.
Value controls the resolution for
decimals.
How much motion is needed to wake
up the readout.
Controls if fractions round up or down.
Controls resolution of 4
(in inches)
Controls which units modes appear.
Auto-off timer (in minutes)
th
decimal place
Default value
0.000
0
0
3
0.004 inches
0 (round down)
1 (.0005"
resolution)
0 (All units)
15