32
www.electrolux.com
12. INSTALLATION
WARNING!
Refer to Safety chapters.
12.1 Building In
600
min. 560
590
12.2 Securing the appliance to
the cabinet
548
min. 550
558
16
20
573
5
3
548
min. 550
558
20
16
min. 560
573
5
3
A
12.3 Electrical installation
This appliance is supplied only with a
main cable.
21
12.4 Cable
114
Cable types applicable for installation or
589
replacement:
594
H07 RN-F, H05 RN-F, H05 RRF, H05
VV-F, H05 V2V2-F (T90), H05 BB-F
594
For the section of the cable refer to the
total power on the rating plate. You can
also refer to the table:
Total power (W)
maximum 1380
21
maximum 2300
114
maximum 3680
589
594
The earth cord (green / yellow cable)
must be 2 cm longer than phase and
594
neutral cables (blue and brown cables).
B
The manufacturer is not
responsible if you do not
follow the safety precautions
from the Safety chapters.
Section of the ca‐
ble (mm²)
3 x 0.75
3 x 1
3 x 1.5