8.0 Appendix A - Maintenance Guide
8.1.6 Hydraulic Fluid Compatibility List
Any of the following oils can be used as a substitute for S-1991-3 hydraulic fluid.
8.2 Electrical System (SCM only)
8.2.1 Fuse Check and Replacement
If the machine is plugged in but the hydraulics will not turn start, a fuse may be blown. The fuse
should be checked first.
To check and replace fuses:
1. Switch off the machine and disconnect main power.
2. Push and turn the fuse holder counter-clockwise. The fuse holder is located beneath the
power switch.
3. Check the fuse for damage and replace as necessary.
4. Push fuse holder into the receptacle and turn clockwise.
22
Product Name
Rykon No. 100
Energol HLP 100
AW 100
Pacemaker XD 100
Super Hydraulic 100
Univis N100
Security AW 100
Knoil R&O AW 100
Tellus 100
Disconnect the main power.
See Section 2.2 Power Lockout Procedure.
Figure 17 – Fuse Location
Distributor
AMOCO
BP
Chevron
Citgo
Conoco
Exxon
Gulf
Kendall
Shell