• The appliance must not be installed behind a decorative door in or-
der to avoid overheating.
• The oven can be located high in a column or under a worktop. Before
fixing, you must ensure good ventilation in the oven space to allow
proper circulation of the fresh air required for cooling and protecting
the internal parts. Make the openings specified on last page accord-
ing to the type of fitting.
ELECTRICAL WARNINGS
• If the oven is provided by the manufacturer without plug:
THE APPLIANCE MUST NOT BE CONNECTED TO THE POWER
SOURCE USING PLUG OR SOCKETS, BUT MUST BE DIRECTLY
CONNECTED TO THE SUPPLY MAINS. The connection to the pow-
er source must be carried out by a suitably qualified professional. In
order to have an installation compliant to the current safety legisla-
tion the oven must be connected only placing an omnipolar break-
er, with contact separation compliant to the requirements for over-
voltage category III, between the appliance and the power source.
The omnipolar breaker must bear the maximum connected load and
must be in line with current legislation. The yellow-green earth ca-
ble should not be interrupted by the breaker. The omnipolar breaker
used for the connection must be easily accessible when the appli-
ance is installed. The connection to the power source must be car-
ried out by a suitably qualified professional considering the polarity
of the oven and of the power source. The disconnection must be
achieved incorporating a switch in the fixed wiring in accordance with
the wiring rules
• If the oven is provided by the manufacturer with plug:
The socket must be suitable for the load indicated on the tag and
must have ground contact connected and in operation. The earth
conductor is yellow-green in colour. This operation should be carried
out by a suitably qualified professional. ln case of incompatibility be-
tween the socket and the appliance plug, ask a qualified electrician
to substitute the socket with another suitable type. The plug and the
socket must be conformed to the current norms of the installation
country. Connection to the power source can also be made by plac-