Section 7
Troubleshooting
Data missing from display reading –
1. Dipole tip must be in contact with soil to record data points
2. Check electrical continuity
3. Check input voltage, 12 v minimum required for controller
No GPS data is coming in during acquisition
1. Check to ensure nothing is obstructing GPS signal (ex. buildings)
2. Is the GPS plugged into 12V and connected to GPS input on OpticMapper
Controller?
3. Follow the steps of the GPS troubleshooting guide to further diagnose problem
OM System Check Fails
1. Verify the window is clean and clear
2. Check to ensure lights are on inside probe
3. Remove wearplate and check for debris behind window
7-1