3-4. Iris Adjustment
Adjustment location: Computer screen
Measuring location: Computer screen
Adjusting method:
1. Click the adjustment software installed from the personal
computer, and the adjustment window will be displayed.
2. Click the START button.
3. In IRIS adjustment mode, Click the AUTO button of IRIS.
4. When "AUTO ADJ. NG" display, carry out the adjustment
again.
3-5. Lens Tracking Adjustment
Adjustment location: Computer screen
Measuring location: Computer screen,
CN204 pin6 (VIDEO OUT)
Measuring equipment: Collimator, Monitor
Subject: Siemens star chart
Adjusting method:
1. Set the camera unit lens 10 ± 5 mm from the collimator.
(Do not enter any light.)
2. Use the " " button to be LENS T in the adjustment window.
3. Display the siemens star chart at centered picture angle.
4. Click the AUTO button of LENS T.
5. When "AUTO ADJ. NG" display, carry out the adjustment
again.
Camera module unit
10 ± 5 mm
3-6. Privacy Masking Compensation
Adjustment location: Computer screen
Measuring location: Computer screen,
CN204 pin6 (VIDEO OUT)
Measuring equipment: Collimator, Monitor
Subject: Siemens star chart
Adjusting method:
1. Set the camera unit lens 10 ± 5 mm from the collimator.
(Do not enter any light.)
2. Use the " " button to select TELE below LENS T in order
to display the masking correction screen.
3.Carefully align the center of the Siemens star chart with
the "+" mark in the center of the screen.
4. Operate "LENS X" with the mouse to adjust the masking
area that is displayed so that it is at an even distance at
left and right from the center of the Siemens star chart.
5. Operate "LENS Y" with the mouse to adjust the masking
area that is displayed so that it is at an even distance
above and below the center of the Siemens star chart.
Collimator
Siemens star chart
6. Use the " " button to select TELE below LENS Y, and
check that there is an even amount of space between the
masking area on the TELE screen and the top, bottom,
left and right edges of the monitor screen.
If there is a large amount of difference in the spaces, re-adjust.
Camera module unit
10 ± 5 mm
-
-
10
Collimator
Siemens star chart