6.
The pump vibrates.
7.
The bearings get too hot.
6.1. Foundations faulty.
6.2. Faulty alignment.
6.3. Impeller
imbalanced
breakage or partial obstruction.
6.4. Shaft bent.
6.5. Air in the liquid.
6.6. Cavitation.
7.1. Faulty alignment.
7.2. The pipelines produce tensions in
the pump.
7.3. High axial thrust.
7.4. Bad
lubrication,
low
grease, too much grease, lack of oil.
6.1. Correct the fault.
6.2. Check the alignment.
through
6.3. Change the impeller, clean the impeller.
6.4. Straighten the shaft or replace this with
a new one.
6.5. Bleed the air from the liquid or prevent
it from getting into the pump.
6.6. Change the operating conditions of the
pump in the installation. Enquire at our
technical service.
7.1. Correct the alignment.
7.2. Eliminate the tensions by loosening the
pipeline.
7.3. Clean the impeller compensation holes.
Adjust the set of sealing rings.
quality
7.4. Use good quality grease, and use the
recommended amount of grease.
Replace the oil levels.