MODEL ADH NEMA
Lethal Voltages Present
Lethal voltages are present inside the ADH
NETCOM. Service should be performed by
qualified personnel only. There are no user
serviceable components inside the chassis.
Abnormal Odor or Smoke
In the event of smoke or a burning or abnormal
odor, immediately interrupt power to the ADH
NETCOM with the POWER switch at the rear of the
unit, unplug the unit, or turn off the circuit breaker
controlling the outlet. Note that only the AC model
of the ADH NETCOM has an ON / OFF switch.
Pneumatics
Each of the air pumps inside the ADH NETCOM
automatic air dehydrator is capable of generating
as much as 24 psig (1,655mbar). Other attached
dry air sources may be capable of generating even
higher pressures. Proper safety practice requires
treating all pneumatic components with care.
Always vent the system to atmospheric pressure
before servicing pneumatic components.
Rack Mounting
Before and after rack mounting the ADH
NETCOM, ensure that the rack is stable. Mounting
of the ADH NETCOM into a rack should be such
that a hazardous condition is not created due to
uneven mechanical loading. Verify that adequate
air flow and power source capacity is available to
the unit. Ensure that the ADH NETCOM maximum
operating temperature of 130°F (55°C) will not be
compromised by other components in the rack.
Ensure reliable earthing of the ADH NETCOM.
ADH NETCOM AC NEMA AC POWER SUPPLY MODULE
REPLACEMENT PROCEDURE
This procedure addresses the removal and replacement of
the AC Power Supply Module in an ADH NETCOM AC NEMA
Automatic Air Dehydrator. It is recommended to read the
entire procedure prior to beginning work.
INVENTORY LIST
Identify the following items in this kit prior to beginning
work.
QTY.
PART NO. DESCRIPTION
1
1
TOOLS REQUIRED
The following tools are needed to perform this procedure:
• Small flat blade screwdriver
• 5/16" Nut driver
• Philips screwdriver
• Long screwdriver
AC POWER SUPPLY MODULE REPLACEMENT PROCEDURE | PART NO.
2
AC POWER SUPPLY MODULE
REPLACEMENT PROCEDURE
23566
AC Power Supply Module
24732
Instruction Manual (this document)
24732
REV
B.0
Need help?
Do you have a question about the NETCOM ADH NEMA and is the answer not in the manual?
Questions and answers