Page 1
MODEL ADH NETCOM ® AUTOMATIC AIR DEHYDRATOR WITH ETHERNET ® NETCOM™ AC NEMA AUTOMATIC AIR DEHYDRATOR AC POWER SUPPLY MODULE REPLACEMENT PROCEDURE Replacement Kit Part Number 24093 Document Part Number 24732 South Bend, Indiana USA networketi.com ADH INSTRUCTION MANUAL | PART NO. 24732...
SAFETY INFORMATION AND WARNINGS Abnormal Odor or Smoke Rack Mounting In the event of smoke or a burning or Before and after rack mounting the abnormal odor, immediately interrupt ADH NETCOM, ensure that the rack power to the ADH NETCOM with the is stable.
TOOLS REQUIRED ADH NETCOM AC NEMA AC POWER The following tools are needed to perform SUPPLY MODULE REPLACEMENT this procedure: PROCEDURE • Small flat blade screwdriver This procedure addresses the removal and • 5/16” Nut driver replacement of the AC Power Supply Module •...
Page 4
AC POWER SUPPLY MODULE REMOVAL AND REPLACEMENT To replace the AC Power Supply Module Disconnect (23566) in an ADH NETCOM AC NEMA both ends, Automatic Air Dehydrator, perform the steps then remove below. orange ethernet cable. Shut off machine power by unplugging the unit.
Page 5
Note the configuration of the five The AC power supply module is located on the inside of the front electrical leads connected to the cover. If not already done, place a existing AC power supply module. brace or prop of some kind under the Refer to Figure 3 and Table 1.
Page 6
Jumper connects across terminals 3 and Insert Philips screwdriver into each access hole to loosen set screws. Figure 4. THE AC POWER SUPPLY MODULE MOUNTING BRACKET SECURING SCREWS. Figure 3. AC POWER SUPPLY MODULE ELECTRICAL CONNECTIONS. Remove the two screws and lock washers connecting the power supply module to the mounting bracket.
Page 7
Using the two screws and lock washers Reconnect the ground wire by removed in step 9, install the new inserting it behind the retaining power supply module to the mounting screw from which it was removed, bracket and torque to 8 in/lb. then tighten the ground wire retaining screw.
Inc. reserves the right to revise this publication and to make changes and improvements products described in this publication without the obligation of ETI, Inc. to notify any person organization such revisions, changes or improvements. No part of this manual may be...