1.0 SERVICE CONNECTIONS

Unless otherwise specified, Electrical Connection to be 120 Volts, 60 Hertz single phase with ground. Furnished with 4 1/2 foot cord with 3 prong
plug. Maximum 4.0 amps.
DRAIN: 2"IPS piped to open floor drain. No Solid Connection. Maximum 24" length before open air gap opening. (No bends or elbows)
GAS CONNECTION: 3/4"IPS supply line required.
CONDENSING COLD WATER: 3/8" O.D. tubing at 25-50 PSI(170-345 kPa)
GENERATOR WATER: 3/8" O.D. tubing at 25-50 PSI(170-345 kPa)
Water quality is the major factor affecting the performance of your appliance. If you are unsure of water quality, consult a
local water treatment specialist and have the water analyzed. Your water supply must be within these general guidelines:
Water which fails to meet these standards should be treated by installation of water conditioner.
FAILURE OR MALFUNCTION OF THIS APPLIANCE DUE TO POOR WATER QUALITY IS NOT COVERED UNDER WARRANTY.
MODEL
BTU/HR.
95,000
SC-5GH
140,000
SC-7GH
SC-10GH
190,000
SC-16GH
24 [610]
36 [914]
SC-16GH ONLY
DIMENSIONS ARE IN INCHES [MM]
WATER QUALITY STATEMENT FOR GENERATOR
Total dissolved solids
Total alkalinity
Silica
Chlorine
pH Factor
GAS SUPPLY PRESSURE (W.C.)
kW/HR.
NATURAL
28
41
6 - 14 INCH
152 - 352mm
56
Less than 60 PPM
Less than 20 PPM
Less than 13 PPM
Less than 1.5 PPM
7.0-8.5
INSTALLED CLEARANCE
PROPANE
LEFT
12 - 14 INCH
0
305 - 352mm
18 [457]
SC-16GH
SAFETY RELIEF
VALVES
15.75 [400]
REAR FLANGED FOOT DETAIL
2 EQUALLY SPACED
Ø
7/16" [11mm] HOLES
ON 2.5 [63] B.C.
4
RIGHT
BACK
6 INCH
0
152mm
1.25 [32]
1.5 [38]
2.5 [64]
1 [25]