SERVICE CONNECTIONS

ELECTRICAL CONNECTION: 1/2" conduit connection to controls. 120VAC-60Hz-1PH2 AMPS per compartment or to be as specified on data plate.
DRAIN: 2"IPS piped to open floor drain. No Solid Connection.
COLD WATER: 3/8" O.D. tubing at 25-50 PSI(170-345 kPa).
S
STEAM SUPPLY: 3/4" female pipe connection for 25-50 PSI(170-345 kPa).
Water quality is the major factor affecting the performance of your appliance. If you are unsure of water quality, consult a
local water treatment specialist and have the water analyzed. Your water supply must be within these general guidelines:
Water which fails to meet these standards should be treated by installation of water conditioner.
FAILURE OR MALFUNCTION OF THIS APPLIANCE DUE TO POOR WATER QUALITY IS NOT COVERED UNDER WARRANTY.
* Pressure reducing valve is required if incoming pressure exceeds 50 PSI(345 kPa).
DIMENSIONS ARE IN INCHES [MM]
S
REAR FLANGED FOOT DETAIL
2 EQUALLY SPACED Ø
HOLES ON 2.5 [63] B.C.
WATER QUALITY STATEMENT
Total dissolved solids
Less than 60 PPM
Total alkalinity
Less than 20 PPM
Silica
Less than 13 PPM
Chlorine
Less than 1.5 PPM
pH Factor
7.0-8.5
2 [51]
2.75 [70]
3.5 [89]
1.5 [38]
28 [711]
10 [254]
18 [457] SB-6SC &
SB-10SC
10 [254]
8.75 [222]
6 [152] SB-16SC
5.75 [146]
0 [0]
7/16" [11mm]
SB-6SC & SB-10SC TOP VIEW
4
24 [610]
0 [0]
2.5 [64]
10 [254]
S
SB-16SC TOP VIEW