stays below 40 ˚C for 2 hours.
The unit will save the current settings after the unit is turned off.
EN
Synchronize/Pair Transmitter and Receiver
The transmitter and receiver were already paired at our manufacturing facility.
Usually you do NOT need to re-synchronize or re-pair the units. You just plug in
the probes, insert batteries, turn on the receiver and the transmitter and wait
for a few seconds, you will see the temperatures shown on both receiver and
transmitter and the units are ready for use.
Option 1:
However, in some unusual cases, the transmitter and receiver are no longer
paired, then you may need to re-synchronize them by following the below steps:
1. Insert two AAA batteries into the receiver, the signal icon on the display will
flash.
2. Insert two AAA batteries into the transmitter, insert the stainless-steel
probes into the corresponding probe sockets in the transmitter. The LCD
screen will show the current temperatures of each probe.
3. Wait for a few seconds, the transmitter will send the signal to the receiver
and once you see the current temperatures on the receiver, the thermometer
is ready for use.
Option 2:
1. Press and hold the
/RESYNC button on receiver for three seconds to enter
the synchronization mode. Then press and hold the
transmitter for three seconds.
2. Wait for a moment until the temperature reading shows on the receiver
display, it means the synchronization/pairing is complete. Your thermometer
is now ready for use.
Note: The synchronization between the transmitter and the receiver won't be
lost even if you replace the batteries.
/RESYNC button on
-8-

Helpful Hints

If the receiver and / or the transmitter do not show the temperature wait for
the probe to reach room temperature. Push the probe jacks harder into the
transmitter and twist them back and forth so they make good contact. If the
problem persists, it is likely the internal probe wire has shorted out either
through moisture or heat damage.
Within the warranty period, contact us and we will send you a replacement
probe with no charge.
If the temperature displayed seems to read too high or the temperature
seems to increase too quickly, check to make sure the probe tip is not
poking through the food. Re-position the probe tip in the center of the
thickest part of food. Avoid touching bone or heavy fat areas.
Cautions:
1. Always wear a heat resistant glove to touch the stainless-steel probe sensors
or wires during or just after cooking. Do not touch with bare hands.
2. Keep the stainless-steel probe sensors and wires away from children.
3. Clean the stainless-steel probes and dry thoroughly after each use.
4. Do not expose the plugs of the stainless-steel probes or the probe sockets
of the transmitter to water or any liquid. This will result in a bad connection
and faulty readings.
5. Wipe the transmitter and receiver with damp cloth.
6. Do not expose the receiver or transmitter to direct heat.
7. Do not use stainless steel probes in a microwave oven.
8. The Probe Thermometer registers temperatures as low as 14 F (-10 C) and
a shigh as 572 ºF (300 ºC). Do not use the stainless probe sensor above
572 ºF. doing so will deteriorate the wire.
9. Not Intended for use by persons aged 12 and under.