Download Print this page

Valor 755CFK Installation And Operation Manual page 3

Circulating fan kit

Advertisement

Available languages

Available languages

Installation with Valor Models Horizon 534 and H4 650
1. Remove the fireplace's front and set aside. (Refer to
the front's installation instructions).
2. Shut off the gas supply to the fireplace and
disconnect the gas supply line from the burner
module.
3. Remove the window.
4. Remove the fuel bed
and panels from the
firebox.
5. Remove the rear log
support.
6. Remove the burner
module (10 screws).
NOTE
Ensure that the metal base of the gas fireplace
enclosure is evenly supported. If the metal base
can flex up and down, it may be a source of
vibration noise when the fan unit is in operation.
Not is the time to correct this.
7. Fit the fan mounting plate to the inside back wall
of the fan compartment, locating on the 2 holes
provided and fasten with the 2 sheet metal screws
provided.
8. Place the fan unit on the fan mounting plate. Ensure
that the fastening stud on the mount lies between
the support legs of the fan and that the fan is
pushed tight against the spacing tabs of the fan
mounting plate.
Center Motor
on Stud
9. Fit the fan retaining clamp between the fan legs and
push it all the way under the tab at the back of
the mounting plate placing the front end over the
threaded stud. Bring the retaining clamp slightly
forward to avoid the offset contacting the mounting
bracket. Fasten with wing nut and washer.
RIGHT SIDE VIEW
Mounting
Fan
plate tab
Retaining clamp
10. Feed the cord set through the clearance hole on the
left-hand side of the liner box.
Hard wiring: The cord set may be removed and
replaced with shielded hard wiring between the
speed control junction box and exterior of the
appliance.
A wiring diagram is shown on page 9 and is also
located on the underside of the control box lid. This
must be done by a qualified electrical installer in
accordance with local codes.
3