Purchasers, installers and users of the new SR30-M2-D1
From:
The Hukseflux Team
Subject:
Overview important changes SR30-M2-D1

Introduction

Congratulations with your purchase of the new SR30-M2-D1 pyranometer!
SR30-M2-D1 is the successor of the popular SR30-D1 pyranometer. Both are digital spectrally
flat Class A (secondary standard) pyranometers, with heating, internal ventilation, tilt sensor
and Modbus over RS-485 output. These fine instruments are made to serve you for a long time.
1)
If this is your first SR30: then please follow SR30-M2-D1 installation instructions
in the SR30-M2-D1 user manual. A copy is sent with your Order Confirmation.
2)
If you are replacing an older SR30-D1 or adding SR30-M2-D1 to a system or
network including SR30-D1's: then please read this document first. It provides a
brief overview of the key differences between SR30-M2-D1 and the SR30-D1 model,
as well as a short installation guide for SR30-M2-D1. Following its instructions allows
you to benefit from the improvements SR30-M2-D1 offers:
2.1)
If you keep using the cabling previously used for SR30-D1:
SR30-M2-D1 can be used with the same 5-pole M12-A connectors and cables
used for SR30-D1 model. However, in order to profit from the improvements
offered by SR30-M2-D1, it is recommended to make minor wiring
modifications. Please read the Specifications and Installation sections in this
memo carefully.
2.2)
If you use new cabling: please read the Specifications and Installation
sections in this memo carefully, followed by the SR30-M2-D1 user manual.
SR30-M2-D1 important changes memo v2009
Hukseflux Thermal Sensors B.V.
Delftechpark 31
2628 XJ Delft
The Netherlands
Tel:
+31 [0]15 2142669
Fax:
+31 [0]15 2574949
URL:
www.hukseflux.com
E-mail: info@hukseflux.com
Memo
Pages:
6
Date:
27 NOV, 2020
Your reference:
-
Our reference:
-
page 1/6

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SR30-M2-D1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Hukseflux SR30-M2-D1

  • Page 1 If this is your first SR30: then please follow SR30-M2-D1 installation instructions in the SR30-M2-D1 user manual. A copy is sent with your Order Confirmation. If you are replacing an older SR30-D1 or adding SR30-M2-D1 to a system or network including SR30-D1’s: then please read this document first. It provides a brief overview of the key differences between SR30-M2-D1 and the SR30-D1 model, as well as a short installation guide for SR30-M2-D1.
  • Page 2 • improved signal integrity through the addition of a dedicated RS-485 common connection This section is limited to electrical specifications of SR30-M2-D1. Other specifications of SR30-M2-D1 are identical or comparable to the SR30-D1 specifications found in the SR30-D1 manual. Modbus registers of SR30-M2-D1 are also identical to the Modbus registers of SR30-D1.
  • Page 3 RS-485 network signal ground, as shown in Figure 1 below. The cables supplied by Hukseflux used for SR30-M2-D1 are identical to the cables used for SR30-D1, however with SR30-M2-D1 all 5 wires are in use as compared to only 4 out of 5 with the SR30-D1 model.
  • Page 4 Hukseflux Thermal Sensors B.V. www.hukseflux.com info@hukseflux.com Figure 2 Comparison of the wiring of SR30-D1 (top) to the wiring of SR30-M2-D1 (bottom) Power: The instrument must be powered by an external power supply, providing an operating voltage in the range specified in Table 1. This is the main power supply for the sensor, using the brown and black signal wires.
  • Page 5 Figure 3 Typical topology of a two-wire RS-485 network, figure adapted from: Modbus over serial line specification and implementation guide V1.02 (www.modbus.org). Neither the power supply nor any isolated interfaces that may be required are shown in this figure. SR30-M2-D1 important changes memo v2009 page 5/6...
  • Page 6 Conclusion: The new SR30-M2-D1 pyranometer offers improvements over its predecessor SR30-D1. • Already owning SR30(’s)? Please read this memo to benefit from the improvements. Need support for SR30-M2-D1? Please consult the user manual on the SR30-M2-D1 • product page and, when using the new Hukseflux Sensor Manager software, the user...