Installation Instructions

WARNING: Before starting the installation,
please refer to the Safety Information section.
• Always switch the power off prior to
beginning the installation.
• Stainless steel is very easily damaged during
installation.
• Wherever possible, protect the rangehood
with the cardboard box or plastic
• A power point must be located within 1.5m
of the power cord exit from the rangehood,
and it should be always accessible to allow
isolation from power during cleaning or
maintenance.
• A 150mm round ducting adapter is supplied,
however all other ducting accessories are not.
• All ducting must comply with building codes
and local requirements.
• If you are re-circulating the air, rather than
ducting, please ensure that the side outlet
grilles are not obstructed in any way as this
will affect the efficiency of the rangehood.
• Ensure that the rangehood is mounted in a
level position, both horizontally and vertically.
This is essential to ensure the rangehood
operates correctly and prevents grease build
up at one end.
IMPORTANT: Never use a silicone around your
rangehood or flue pieces. Never install the
rangehood or flue pieces into the plaster ceiling
which prevents easy access to the rangehood for
servicing requirements.
IMPORTANT: Before installing your rangehood,
please record the details of your rangehood's
rating label (located within the rangehood,
behind the aluminium grease filters) into the form
on page 19. This will be helpful should you need
to contact our service team in the future.
POSITIONING THE RANGEHOOD
IMPORTANT: The height of the rangehood
underside must be a minimum of 600mm* to a
maximum 800mm from the top of your cooktop
surface (for gas cooktops this is the top of the
gas burner).
* If the installation instructions for your cooktop
specify a greater distance than the minimum,
then that shall be the minimum height for
installation.
COOKTOP FUEL TYPE:
Gas (multiple burners
with maximum 45.4 MJ/h
total output and no single
burner exceeding
16.2 MJ/h output)
Gas (multiple burners with
total output greater than
45.4 MJ/h but less than
77.8 MJ/h, and no single
burner exceeding
17.3 MJ/h output)
Gas (single burner
not exceeding
21.6 MJ/h output)
Gas (single burner with
an output greater than
21.6 MJ/h but not
exceeding 29.2 MJ/h)
Electric
10
DIMENSION A
Minimum*
Maximum
650mm
800mm
760mm
800mm
650mm
800mm
760mm
800mm
600mm
800mm