EXPERT 2V3SA
Display:
T° & Inlet
Change Password — The user can define
a password to restrict access to certain
functions (USER SETUP and TEST MODE).
The password must be entered each time
one of these functions is selected. When
the correct password is entered, it does
not need to be reentered until the display
times out (i.e. after 15 minutes of inactiv-
ity). The password is a sequence of three
numbers from 0 to 99. To disable it, set
the password to 0, 0, 0. By default, the
password is disabled. *Use the MODIFY
button to step from a digit to the next.
New password?
00 ** **
Program Version Number — The version
number of the controller is displayed.
EXPERT 2V3SA
Version X.X
4.5.

Clean Mode

The clean mode is used to interrupt regular
operations of the controller when the room
is empty. When this mode is enabled, the
controller only provides a minimum level of
heat and ventilation (optional). If minimum
ventilation is used in the clean mode, the
air inlet will open to its respective minimum
ventilation position; otherwise it will remain
closed.
Cleaning the room: A soaking output can be
used to clean up the room. If this output is
enabled, it will automatically start running
according to a user-defined timer at clean
mode startup. Refer to chapter 8 on page
31 to get further information about the
soaking output.
Clean mode set point: During the clean mode,
the fans that are used to provide minimum
ventilation and the heaters operate accord-
ing to the clean mode set point: the heaters
turn on when the room temperature is lower
than the clean mode set point and fans turn
on when temperature is higher than this set
point.
Low temperature alarm: The controller can
sound an alarm if temperature gets too low
while being in clean mode. Refer to section
12.1.3 to set this alarm limit.
EXPERT 2V3SA, rev. 10
15