Klimawent SPARK-CHEM-160/1500/Ex Use And Maintenance Manual

Chem-proof ex roof fans

Advertisement

Quick Links

Use and Maintenance Manual
Chem-proof Ex roof fans
ATEX marking:
Contents:
1.
Introductory Remarks .........................................................................2
2.
Application ..........................................................................................3
3.
Reservations of Producer .....................................................................3
4.
Technical Data ....................................................................................4
5.
Structure and Function .......................................................................5
6.
Assembly and Start-up .........................................................................6
7.
Operational Use ...................................................................................8
8.
Troubleshooting Guide ........................................................................8
9.
Maintenance .......................................................................................8
10.
Occupational Health and Safety ...........................................................9
11.
Transport and Storage .........................................................................9
12.
Terms of warranty ...............................................................................10
13.
14.
Sample of the Declaration of Conformity .............................................15
808W18 SPARK-CHEM-160/1500/Ex 04.06.2019/EN
808W19 SPARK-CHEM-200/1500/Ex 04.06.2019/EN
808W20 SPARK-CHEM-250/1500/Ex 04.06.2019/EN
808W21 SPARK-CHEM-315/1500/Ex 04.06.2019/EN
04.06.2019
1
SPARK-CHEM/Ex
II 2 G c Ex e II T3
chem-proof Ex roof fan SPARK-CHEM/Ex

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SPARK-CHEM-160/1500/Ex and is the answer not in the manual?

Questions and answers

Summary of Contents for Klimawent SPARK-CHEM-160/1500/Ex

  • Page 1: Table Of Contents

    Occupational Health and Safety ............9 Transport and Storage .................9 Terms of warranty ................10 Table of resistance of PVC against various substances ......11 Sample of the Declaration of Conformity ..........15 808W18 SPARK-CHEM-160/1500/Ex 04.06.2019/EN 808W19 SPARK-CHEM-200/1500/Ex 04.06.2019/EN 808W20 SPARK-CHEM-250/1500/Ex 04.06.2019/EN 808W21 SPARK-CHEM-315/1500/Ex 04.06.2019/EN 04.06.2019...
  • Page 2: Introductory Remarks

    1. Introductory Remarks The purpose of the present Use and Maintenance Manual is to supply User with directions wi- thin the range of application, installation, start-up and the use of the SPARK-CHEM/Ex chem - explosion-proof stand fans . Installing, start up and operational use are exclusively admissible after getting acquaint- ted with the contents of the Use and Maintenance Manual.
  • Page 3: Application

    2. Application SPARK-CHEM/Ex chem- explosion proof stand fans are intended for use in areas of explosion risk, where explosive atmosphere , (i.e. mixture of flammable substances in form of gas and va- pour with the air, whereby after ignition – in atmospheric conditions – the burning mass would expand within the whole non-burning mixture) is likely to occur.
  • Page 4: Technical Data

    Weight nous voltage rate volume vacuum from distance Type of the fan rotations flow [1/min] [kW] [Pa] [kg] [dB(A)] SPARK-CHEM-160/1500/Ex 1500 3 x 400 0,12 10,6 SPARK-CHEM-200/1500/Ex 1500 3 x 400 0,18 1330 14,2 SPARK-CHEM-250/1500/Ex 1500 3 x 400 0,37...
  • Page 5: Structure And Function

    [mm] [mm] [mm] [mm] [mm] [mm] SPARK-CHEM-160/1500/Ex SPARK-CHEM-200/1500/Ex SPARK-CHEM-250/1500/Ex SPARK-CHEM-315/1500/Ex 5. Structure and Function Structure of the fan is illustrated on Fig. No.3. The subsequent constructional elements of the fan (except the impeller) are of antistatic plastic (PE EL) . The impeller is made of stainless steel, therefore it is possible to forward the chemically aggressive and flammable gases and vapours as a mixture with the air.
  • Page 6: Assembly And Start-Up

    Fig. No.3 – Structure of the fans type SPARK-CHEM/Ex To the impeller is fastened a cast iron hub. The hub along with the impeller is mounted at the motor journal. The motor (in Ex execution) is installed on a supporting plate. The supporting plate is formed of antistatic plastic (PE EL) and is of round shape with the bent outwards flange.
  • Page 7 6.1. Guidelines of installing: a/ VENTILATION INSTALLATION – to which SMART-CHEM/Ex fans are installed, should be designed and carried out in accordance with the being in force valid re- gulations and standards, with reference to the local explosion hazard. b/ ELECTRICAL INSTALLATION – where SMART-CHEM/Ex fans shall be con- nected –...
  • Page 8: Operational Use

    CAUTION: Isolating switch ought to be installed beyond the explosion risk area, near the fan. 7. Operational Use Construction and reliable execution of the fan provide longevity of operational use without the everyday routine technical supervision. Periodically, examine the mechanical and electri- cal connections, the state of grounding, and additionally provide efficient cooling to the motor.
  • Page 9: Occupational Health And Safety

    Technical revisions on the fan must be performed exclusively by an authori- sed person with qualifications. Additionally, the fan should necessarily be disconnected from the power supply system. During the technical revisions, follow the instructions included in the User’s Manual of the motor, that constitute integral part of the main Use and Maintenance Manual of the fan.
  • Page 10: Terms Of Warranty

    12. Terms of warranty The period of warranty for the purchased device is indicated in the “ Card of Warranty”. The war ranty does not comprise: ● mechanical damages and malfunctions caused by User, ● device failures caused during use which was in contradiction with the purpose of opera- tional use and with the present Use and Maintenance Manual, ●...
  • Page 11: Table Of Resistance Of Pvc Against Various Substances

    13. Table of resistance of PVC against various substances Environment Concentration % Acetone – – – – Pure amyl alcohol Ethyl alcohol (ethanol) Non-fermentative isopropyl alcohol 70 - 99 Methyl alcohol (methanol) – Methyl alcohol (aqueous solution) Ammonia, aqueous solution Potassium nitrate, aqueous solution saturated Sodium nitrate, aqueous solution...
  • Page 12 Environment Concentration % Ammonia phosphate Glycerine Glycol Heptane Izopropanol Chromium bath, technical Methyl-ethyl ketone – – – – Cresols – – – – Accumulator acid (H Nitric acid 10 / 50 + + / + + + +/ + Boric acid Hydrocyanic acid Citric acid saturated...
  • Page 13 Environment Concentration % Soybean oil Turpentine oil Transformer oil Mineral oils (without aromatic hydrocarbons) Furnace oils Silicone oils Engine oils, car oils Pine oil Vapours of ethoxyl amines – – – – Vapours of chlorides Vapours of ferrous chloride FeCl Vapours of acetic acid Vapours of hydrochloric acid Vapours of oxy-oxygen fatty alcohols...
  • Page 14 Environment Concentration % Sodium tio-sulphate (fixative) saturated Toluene – – – – Chlorinated lime Potassium carbonate, aqueous solution saturated Sodium carbonate, aqueous solution saturated Water Chlorinated water saturated Aqua regia (nitro-hydrochloric acid) Seawater Sodium hydroxide Sodium hydroxide (caustic soda) resistant conditionally resistant with the occurrence hazard of tensioning stress cracks conditionally resistant...
  • Page 15: Sample Of The Declaration Of Conformity

    Declaration of conformity EC No. …………….. Manufacturer (eventually the authorized representative / importer): name: KLIMAWENT S.A. address: 81-571 Gdynia, Chwaszczyńska 194 A person, authorized for issuing the technical documentation: Teodor Świrbutowicz, KLIMAWENT S.A. hereby declares that the appliance: name: chem-proof Ex roof fans...
  • Page 16 NOTES: chem-proof Ex roof fan SPARK-CHEM/Ex 04.06.2019...