Klimawent STRONG-5000-S Use And Maintenance Manual

Klimawent STRONG-5000-S Use And Maintenance Manual

Filtering unit

Advertisement

Quick Links

Use and Maintenance Manual
Filtering unit
Manufacturer:
KLIMAWENT S.A.
81-571 Gdynia; ul. Chwaszczyńska 194
phone 58 629 64 80; 58 771 43 40
phone 58 629 64 80
e-mail: klimawent@klimawent.com.pl
www.klimawent.com.pl
Contents:
1.
Introductory Remarks ....................................................................................................... 2
2.
Application......................................................................................................................... 2
3.
Reservations of Producer ................................................................................................. 2
4.
Technical Data ................................................................................................................... 3
5.
Structure and Function ..................................................................................................... 4
6.
Assembly and Start-up ..................................................................................................... 6
7.
Operational Use ................................................................................................................. 8
8.
Troubleshooting Guide ..................................................................................................... 21
9.
Maintenance ...................................................................................................................... 21
10.
Occupational Health and Safety ....................................................................................... 22
11.
Transport and Storage ...................................................................................................... 22
12.
Terms of warranty ............................................................................................................. 22
13.
Sample of the Declaration of Conformity ........................................................................ 23
01.10.2019
1
STRONG-5000-S
804U59 STRONG-5000-S 01.10.2019/EN
filtering unit STRONG-5000-S

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the STRONG-5000-S and is the answer not in the manual?

Questions and answers

Summary of Contents for Klimawent STRONG-5000-S

  • Page 1: Table Of Contents

    81-571 Gdynia; ul. Chwaszczyńska 194 phone 58 629 64 80; 58 771 43 40 phone 58 629 64 80 e-mail: klimawent@klimawent.com.pl www.klimawent.com.pl 804U59 STRONG-5000-S 01.10.2019/EN Contents: Introductory Remarks ....................... 2 Application......................... 2 Reservations of Producer ....................2 Technical Data ........................3 Structure and Function .....................
  • Page 2: Introductory Remarks

    Construction of the STRONG-5000-S filtering unit meets the requirements of the current state of te- chnology as well as the safety and health assurances included in: ...
  • Page 3: Technical Data

    4200 73,5 Volume flow has been measured at clean filters. Acoustic pressure level was taken at the filtering unit with the additional silencer applied. Ingress protection of the motor housing IP54. Fig. No.1 – Flow Chart filtering unit STRONG-5000-S 01.10.2019...
  • Page 4: Structure And Function

    – i.e. the discharge connection is not closed and the air is expelled back into the process room, it is recommended to apply additional sound absorbing elements (see Fig. No.3). As optional accessories KLIMAWENT S.A. offers additional sound-absorbing set consisting of: – connecting fitting piece – an elbow 400x400 mm, –...
  • Page 5 Fig. No.2 – STRONG-5000-S – Structure and dimensions filtering unit STRONG-5000-S 01.10.2019...
  • Page 6: Assembly And Start-Up

    Prior to installing check the load carrying capacity of the floor. The legs of the STRONG-5000-S device are divided (sectioned) , so the total height of the device can be reduced for transport. Right after its delivery at the site of use, the legs have to be assembled by screwing up to the base (a set of screws/bolts is delivered by KLIMAWENT S.A.).
  • Page 7 -joint locks. Finally, close the door of the chamber of filters and tighten up thoroughly the screw locks. Having replaced the cartridge filters, connect the filtering unit to the power supply. Fig. No.5 – STRONG-5000-S – Connection Diagram filtering unit STRONG-5000-S...
  • Page 8: Operational Use

    7. Operational Use Control unit, ZE-STRONG-5000-S energises the fan, and additionally serves for controlling the pneumatic system of filters regeneration . The control unit is delivered along with the device. 1. Structure of the control unit a. external part – consisting of a control panel, containing subsequent elements: –...
  • Page 9 – contactors K1M, K2M, K3M – B1 – controller UFOv5.1 – controls the function of the electromagnetic valves – supervisory relay CKF – time relay K1T – keyboard – terminal strip Fig. No.8 – ZE-STRONG-5000-S – inside filtering unit STRONG-5000-S 01.10.2019...
  • Page 10 OK – correct state of the functional elements of the board UFOv5.1 EO1 – alarm of the memory of the data EO2 – alarm of the sensor of the temperature measuring EO3 – alarm of the RTC clock filtering unit STRONG-5000-S 15.10.2019...
  • Page 11 MANUAL – mode of continuous work PROG – mode of work as a function of time programmer Screen MODES MODES -> Sub-menu of the setting groups MODES Screen SETTINGS SETTINGS -> Sub-menu of the adjustments group SETTINGS filtering unit STRONG-5000-S 01.10.2019...
  • Page 12 Screen INPUTS / OUTPUTS INPUTS / -> Sub-menu of the settings INPUTS / OUTPUTS OUTPUTS Screen SETTING OF TIME Day = Tu hour 10:00 To adjust the days of the week and the time Lang = ANG filtering unit STRONG-5000-S 15.10.2019...
  • Page 13 COOL – activated function of cooling by means of the output OUT5 [AL24V akt.]:{OFF I ON} OFF – blocking of the occurring alarm in case of lack of the suppor- ting power supply 24VAC for outputs of electro-valves T1÷T4 ON – alarm AL24V activated filtering unit STRONG-5000-S 01.10.2019...
  • Page 14 OFF – blocking of the possibility of switching on by means of the input DI5 of the status NSTR ON – stop of the status NSTR active Input DI4 makes the same function as the button START S1 on the elevation console filtering unit STRONG-5000-S 15.10.2019...
  • Page 15 NSTR (switching on within the level) ON – stop of the status NSTR activated (switching on within the level) In case when [DI8. START]=ON and [DI8stop]=ON input DI8 fulfils the function of remote control ON / OFF of the status NSTR filtering unit STRONG-5000-S 01.10.2019...
  • Page 16 Ton PowPause = 10s Time T12 – duration of the impulse of the supply of the electro-valves [TonPowPause]:{1 - 50 sec} TonPowPause – duration of the status STB (initialising of the system after the power supply is switched on) filtering unit STRONG-5000-S 15.10.2019...
  • Page 17 Time T22 – duration of the break (idle time) between the impulses of the power supply of the electro-valves, during the status SKF [Lsekwen Loff]:{0-20} Lsekwen Loff – number of sequences (4 cycles of pulsing each) – of pulsing – for the status SKF filtering unit STRONG-5000-S 01.10.2019...
  • Page 18 Sub-menu INPUT / OUTPUT Screen INPUTS / OUTPUTS 1/3 DI: 000111000 DO: 101010 (DI) – status of the digital inputs – from DI0 up to DI9 (DO) – status of the digital outputs – from DOUT0 up to DOUT5 filtering unit STRONG-5000-S 15.10.2019...
  • Page 19 Screen INPUTS / OUTPUTS 3/3 Tb = +25.5 StanZas 24 = OK (Tb) – measuring of temperature on the controller (StanZas 24V) – the state of transformer fuse 24VAC of the power supply of the electromagnetic valves Digital inputs filtering unit STRONG-5000-S 01.10.2019...
  • Page 20 H3). The signal controlling the correctness of power supply 24VAC is for operating the electromag- netic valves. The controller indicates on display the lack of supply in case when for example the fuse is burned out. filtering unit STRONG-5000-S 15.10.2019...
  • Page 21: Troubleshooting Guide

    From time to time, after the completed work, clean the chambers of electromagnetic valves from the accumulated dust. Every time, before emptying the waste container, it is important to “tap” the discharge hopper chamber (to strike all the pollutants dawn into the waste container). filtering unit STRONG-5000-S 01.10.2019...
  • Page 22: Occupational Health And Safety

    11. Transport and Storage STRONG-5000-S filtering unit has to be transported in two assemblies protected in foil , placed on on transport pallets. For the transport time the device should be placed in vertical position and protected from an uncontrolled overturn and displacement.
  • Page 23: Sample Of The Declaration Of Conformity

    Declaration of conformity EC No. …………….. Manufacturer (eventually the authorized representative / importer): name: KLIMAWENT S.A. address: 81-571 Gdynia, Chwaszczyńska 194 A person, authorized for issuing the technical documentation: Teodor Świrbutowicz, KLIMAWENT S.A. hereby declares that the appliance: name: filtering unit...
  • Page 24 NOTES: filtering unit STRONG-5000-S 15.10.2019...

Table of Contents