Klimawent SMART-N Series Use And Maintenance Manual

Klimawent SMART-N Series Use And Maintenance Manual

Radial roof fans

Advertisement

Use and Maintenance Manual
Radial roof fans
Contents:
1.
Introductory Remarks ............................................................................................... 2
2.
Application ................................................................................................................. 2
3.
Reservations of Producer......................................................................................... 2
4.
Technical Data ........................................................................................................... 3
5.
Structure and Function ........................................................................................... 10
6.
Assembly and Start-up ........................................................................................... 12
7.
Operational Use ....................................................................................................... 15
8.
Trouble Shooting Guide ......................................................................................... 16
9.
Maintenance ............................................................................................................ 16
10.
Occupational Health and Safety ............................................................................ 17
11.
Transport and Storage ............................................................................................ 17
12.
Terms of warranty ................................................................................................... 17
13.
Sample of the Declaration of Conformity .............................................................. 18
812W60 SMART-160/3000-N 31.05.2019/EN
812W61 SMART-200/1000-N 31.05.2019/EN
812W62 SMART-200/1500-N 31.05.2019/EN
812W63 SMART-200/3000-N 31.05.2019/EN
812W64 SMART-250/1000-N 31.05.2019/EN
812W65 SMART-250/1500-N 31.05.2019/EN
812W66 SMART-250/3000-N 31.05.2019/EN
812W67 SMART-315/1000-N 31.05.2019/EN
812W68 SMART-315/1500-N 31.05.2019/EN
812W69 SMART-315/3000-N 31.05.2019/EN
31.05.2019
1
SMART-N
812W70
812W71
812W72
812W73
812W74
812W75
812W76
812W77
812W78
RADIAL ROOF FANS SMART-N
SMART-400/750-N
SMART-400/1000-N
SMART-400/1500-N
SMART-500/750-N
SMART-500/1000-N
SMART-630/750-N
SMART-630/1000-N
SMART-710/750-N
SMART-710/1000-N
31.05.2019/EN
31.05.2019/EN
31.05.2019/EN
31.05.2019/EN
31.05.2019/EN
31.05.2019/EN
31.05.2019/EN
31.05.2019/EN
31.05.2019/EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SMART-N Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Klimawent SMART-N Series

  • Page 1: Table Of Contents

    Use and Maintenance Manual SMART-N Radial roof fans Contents: Introductory Remarks ....................2 Application ......................... 2 Reservations of Producer..................2 Technical Data ......................3 Structure and Function ................... 10 Assembly and Start-up ................... 12 Operational Use ....................... 15 Trouble Shooting Guide ..................16 Maintenance ......................
  • Page 2: Introductory Remarks

    1. Introductory Remarks The purpose of the present Use and Maintenance Manual is to supply User with directions wi- thin the range of application, installation, start-up and the operational use of the SMART-N radial roof fans . Installing, start up and operational use are exclusively admissible after getting acquaint- ted with the contents of the Use and Maintenance Manual.
  • Page 3: Technical Data

    D. Protect the housing from mechanical damage. E. Prior to installing, check the load capacity of the constructional elements where the fan will be mounted. Unsure installing could cause hazard to personnel / people in vicinity and effect in damage of the device. F.
  • Page 4 Flow charts Table No.2 SMART-160/3000-N Acoustic pressure level [dB(A)] outlet inlet 1 [m] 5 [m] 10 [m] 15 [m] 1 [m] Table No.3 SMART-200/1000-N Acoustic pressure level [dB(A)] outlet inlet 1 [m] 5 [m] 10 [m] 15 [m] 1 [m] RADIAL ROOF FANS SMART-N 31.05.2019...
  • Page 5 SMART-200/1500-N Acoustic pressure level [dB(A)] outlet inlet 1 [m] 5 [m] 10 [m] 15 [m] 1 [m] SMART-200/3000-N Acoustic pressure level [dB(A)] outlet inlet 1 [m] 5 [m] 10 [m] 15 [m] 1 [m] Table No.4 SMART-250/1000-N Acoustic pressure level [dB(A)] outlet inlet 1 [m]...
  • Page 6 Table No.5 SMART-315/1000-N Acoustic pressure level [dB(A)] outlet inlet 1 [m] 5 [m] 10 [m] 15 [m] 1 [m] SMART-315/1500-N Acoustic pressure level [dB(A)] outlet inlet 1 [m] 5 [m] 10 [m] 15 [m] 1 [m] SMART-315/3000-N Acoustic pressure level [dB(A)] outlet inlet 1 [m]...
  • Page 7 Table No.6 SMART-400/750-N Acoustic pressure level [dB(A)] outlet inlet 1 [m] 5 [m] 10 [m] 15 [m] 1 [m] SMART-400/1000-N Acoustic pressure level [dB(A)] outlet inlet 1 [m] 5 [m] 10 [m] 15 [m] 1 [m] SMART-400/1500-N Acoustic pressure level [dB(A)] outlet inlet 1 [m]...
  • Page 8 Table No.7 SMART-500/750-N Acoustic pressure level [dB(A)] outlet inlet 1 [m] 5 [m] 10 [m] 15 [m] 1 [m] SMART-500/1000-N Acoustic pressure level [dB(A)] outlet inlet 1 [m] 5 [m] 10 [m] 15 [m] 1 [m] RADIAL ROOF FANS SMART-N 31.05.2019...
  • Page 9 Table No.8 SMART-630/750-N Acoustic pressure level [dB(A)] outlet inlet 1 [m] 5 [m] 10 [m] 15 [m] 1 [m] SMART-630/1000-N Acoustic pressure level [dB(A)] outlet inlet 1 [m] 5 [m] 10 [m] 15 [m] 1 [m] 31.05.2019 RADIAL ROOF FANS SMART-N...
  • Page 10: Structure And Function

    Table No.9 SMART-710/750-N Acoustic pressure level [dB(A)] outlet inlet 1 [m] 5 [m] 10 [m] 15 [m] 1 [m] SMART-710/1000-N Acoustic pressure level [dB(A)] outlet inlet 1 [m] 5 [m] 10 [m] 15 [m] 1 [m] 5. Structure and Function SMART-N radial roof fans are of original construction of bent steel profiles, making up a ske- leton of streamline and robust properties.
  • Page 11 On separate order, are delivered isolating switches, that are required to disconnect the po- wer supply during installing and servicing. In the Fig. No.1 are displayed dimensions of the SMART-N fans in subsequent sizes (except for fans of 3000 r.p.m.). Fig.
  • Page 12: Assembly And Start-Up

    In the Fig. No.2 are displayed dimensions and structure of the fans SMART-N of rotational speed 3000 r.p.m. Fig. No.2 – SMART-N fans of 3000 r.p.m. – structure and dimensions Table No.11 – Dimensions of the fans type SMART-N of rotational speed 3000 r.p.m. ØC ØD ØE...
  • Page 13 Having placed the fan on the roof base, screw up precisely all the bolts between the fan connec- tion flange and the roof base (see Fig. No.3) and finally install the hood. As the impeller is uncovered and unprotected, handle with care while the fan is lifted (transported vertically) and positioned at the place of operation.
  • Page 14 It is important to install the isolating switch (IS), to cut off the power supply for the time of servi- cing / maintenance. Isolating switch is an additional accessory – KLIMAWENT S.A. delivers it on separate order. User installs the switch on one’s own in a convenient place.
  • Page 15: Operational Use

    Before this, remove the fan hood to get free access to the connection box of the fan motor. Having completed all the connections, reinstall the fan hood. Additionally, it is important to select the suitable sort and section of the supply cable and pro- tection from short-circuit- and overload effects, according to the local conditions.
  • Page 16: Trouble Shooting Guide

    User. Isolating switch ought to be installed within reach of the servicer. IS isolating switches are offered by KLIMAWENT S.A. as additional accessory. The way of con- nection is shown in the operation manual of the insolating switch (IS).
  • Page 17: Occupational Health And Safety

    10. Occupational Health and Safety Start up and the operational use is only admissible exclusively after getting acquainted with the contents of the present Use and Maintenance Manual. The fan will not cause any hazard to User / personnel, if it is stably installed on the roof base or another supporting struc- ture of appropriate load carrying capacity.
  • Page 18: Sample Of The Declaration Of Conformity

    Declaration of conformity EC No. …………….. Manufacturer (eventually the authorized representative / importer): name: KLIMAWENT S.A. address: 81-571 Gdynia, Chwaszczyńska 194 A person, authorized for issuing the technical documentation: Teodor Świrbutowicz, KLIMAWENT S.A. hereby declares that the appliance: name: Radial roof fan...
  • Page 19 NOTES: 31.05.2019 RADIAL ROOF FANS SMART-N...
  • Page 20 NOTES: RADIAL ROOF FANS SMART-N 31.05.2019...