Omron E8F2 Manual page 22

Pressure sensor
Hide thumbs Also See for E8F2:
Table of Contents

Advertisement

E8F2
Precautions
J ENVIRONMENT
Do not use the Sensor in locations subject to explosive or
flammable gases.
Do not use the Sensor in an environment subject to corrosive
or combustible gases.
Make sure that the Sensor is free of water.
J AVOID DAMAGE TO THE E8F2
Do not impose any voltage exceeding the rated voltage on
the E8F2.
Do not short-circuit the load connected to the E8F2.
When supplying power to the E8F2, make sure that the po-
larity of the power is correct.
J WIRING
Do not wire power lines or high-tension lines adjacent to the
lines of the E8F2.
If no linear output is used, cut the gray lead wire short and
apply insulating tape to the lead wire so that it will not come
into contact with any other terminal.
NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4.
OMRON ELECTRONICS LLC
One East Commerce Drive
Schaumburg, IL 60173
1-800-55-OMRON
Cat. No. CEDSAX4
R
OMRON ON- -LINE
Global -- http://www.omron.com
USA -- http://www.omron.com/oei
Canada -- http://www.omron.com/oci
11/01
Specifications subject to change without notice.
J MOUNTING
Mount the Sensor so that ultrasonic vibrations will not be
applied directly to the Sensor.
Do not insert any wire into the pressure port. Doing so may
damage the pressure elements and cause a malfunction.
Do not apply a tensile strength in excess of 50 N (11.25 lbs)
to the cords or connectors.
The pressure-introducing section (aluminum die-cast made)
is fixed with tapered 1/8 NPT male screws and M5 female
screws. When using tapered screws, use tapered 1/8 NPT
female screws.
Wrap the tapered 1/8 NPT male screws with sealing tape to
prevent any leakage. Tighten the male screws to a torque of
10 NSm (7.38 ftSlbs) max.
Tighten M5 female screws to a torque of 2 NSm
(1.48 ftSlbs) max.
Tightening each male screw by using a 12-mm wrench to
hold its hexagonal head, not the screw itself.
E8F2
When attaching the Mounting Bracket to the Sensor, make
sure that each M3 screw is tightened to a torque of
0.5 NSm (0.37 ftSlbs) max.
OMRON CANADA, INC.
416-286-6465
E8F2
Hexagonal head
885 Milner Avenue
Scarborough, Ontario M1B 5V8
Printed in U.S.A.