Section 4
PReSeT MeMORY MODULe
This module stores 8 different weld schedules for EACH WELD TOOL. This module stores all the weld parameters
for a given setting. These parameters include:
Main arc time
Hammer Mode
The module also stores settings for option features:
Gas Mode
Upper Time Control Limit
Upper Current Control Limit
Reviewing Stored Settings
Press & hold the button next to the memory location you wish to review. The LED next to that location will start to
flash and the display will change to the review screen (Once the LED flashes you may release the button).
Main arc current Pilot arc time
Gas Pre-Flow Time
Lower Time Control Limit
Lower Current Control Limit
The Preset Memory module has a "write-on" surface next to each decal to jot
down a reminder as to the program stored in that location. Use a felt tipped
pen to make your notes. Do not use pencil or ball point pen because these will
damage the "write-on" surface. The felt tip markings can be removed with a
damp cloth.
Recalling Stored Settings
To recall a weld schedule, press the button next to the setting you want
to recall. In multi-weld tool systems be sure that the weld tool is correctly
selected for the settings you wish to recall. The display will change to show
the recalled values as well as showing which program number you are using.
Additionally, the LED next to the program you selected will light up. You are
ready to weld with these settings.
Optional features
Pilot arc current
Gas Post-Flow Time
Gas Off-Delay