This manual MUST be given to the user of the product.
BEFORE using this product, this manual MUST be read and saved for
future reference.
Invacare® Platinum® Oxygen
Concentrator
IRC9LXO2AWQ
en HomeFill® System Compatible
User Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Platinum IRC9LXO2AWQ and is the answer not in the manual?

Questions and answers

Summary of Contents for Invacare Platinum IRC9LXO2AWQ

  • Page 1 Invacare® Platinum® Oxygen Concentrator IRC9LXO2AWQ en HomeFill® System Compatible User Manual This manual MUST be given to the user of the product. BEFORE using this product, this manual MUST be read and saved for future reference.
  • Page 2 All rights reserved. Republication, duplication or modification in whole or in part is prohibited without prior written permission from Invacare. Trademarks are identified by ™ and ®. All trademarks are owned by or licensed to Invacare Corporation or its subsidiaries unless otherwise noted.
  • Page 3: Table Of Contents

    6.3.8 Elapsed Time Meter (Hour Meter) ....27 Contents 7 Maintenance ........28 7.1 Service Life .
  • Page 4: General

    Invacare® Platinum® Oxygen Concentrator Symbols in Documentation 1 General General Warning Sign 1.1 Symbols The background color inside the triangle is yellow on product labels. Signal words are used in this manual and apply to hazards or unsafe practices which could result in personal injury or Read Manual property damage.
  • Page 5 General **This product complies with Directive Keep Dry 93/42/EEC concerning medical devices. The launch date of this product is stated in Transport and Storage Temperature the CE declaration of conformity. EC Representative -29C Transport and Storage Humidity Reference Number Serial Number Alternating Current Type BF equipment Symbols on Product...
  • Page 6: Intended Use

    Risk of Injury or Damage 1.2 Intended Use Use of this product outside of the intended use The intended function and use of the Invacare Platinum and specifications has not been tested and may Oxygen Concentrator is to provide supplemental oxygen to...
  • Page 7: Indications For Use

    1.4 Description The Invacare Platinum concentrator is used by patients with respiratory disorders who require supplemental oxygen. The device is not intended to sustain or support life.
  • Page 8: Safety

    Invacare® Platinum® Oxygen Concentrator 2 Safety Double insulation label is located on the back of the concentrator at the base. 2.1 Label Locations IRC9LXO2AWQ Serial number label is located on the resonator intake assembly. Specification label is located on the back of the concentrator at the base.
  • Page 9 Invacare for repair. – DO NOT allow smoking within the same room – THE INFORMATION IN THIS DOCUMENT IS where the oxygen concentrator or any oxygen SUBJECT TO CHANGE WITHOUT NOTICE.
  • Page 10 Invacare® Platinum® Oxygen Concentrator DANGER! DANGER! Risk of Death, Injury or Damage from Fire Risk of Death or Injury from Electric Shock Textiles, oil or petroleum substances, grease, To reduce the risk of burns, electrocution, death greasy substances and other combustibles are...
  • Page 11 – Monitor patients using this device who are Invacare and are not recommended for use unable to hear or see alarms or communicate with Invacare products.
  • Page 12 WARNING! – Users should contact your dealer or Invacare Risk of Injury or Damage for service. To prevent injury or damage from misuse: – NEVER leave concentrator unattended when plugged in.
  • Page 13: Radio Frequency Interference

    For additional information, refer to 10.2 Electromagnetic Compliance (EMC), page 39. WARNING! – Use of accessories and cables other than those specified or provided by Invacare could result in increased electromagnetic emissions or decreased electromagnetic immunity of this equipment and result in improper operation.
  • Page 14: Components

    When not in use, the plug Oxygen Outlet provided with the concentrator should be inserted Flowmeter into the outlet fitting. For more information about the HomeFill System, contact your Invacare dealer. Oxygen Purity Indicator Lights/Fault and Power Indicator Lights Power Switch Circuit Breaker...
  • Page 15: Pneumatic Diagram

    Components 3.2 Pneumatic Diagram Fig. 3-2 Concentrator with Humidifier Fig. 3-1 Concentrator without Humidifier 1195054-B...
  • Page 16: Accessories

    Invacare® Platinum® Oxygen Concentrator 4 Accessories 4.1 Optional Accessories There are many different types of humidifiers, oxygen tubing, cannulas and masks that can be used with this device. You should contact your local home care supplier for recommendations on which of these devices will be best for you.
  • Page 17: Setup

    Setup 1. Check for any obvious damage to the carton or its 5 Setup contents. If damage is evident, notify the carrier, or your local dealer. 5.1 Unpacking 2. Remove all loose packing from the carton. 3. Carefully remove all the components from the carton. Unless the oxygen concentrator is to be used IMMEDIATELY, leave concentrator in its packaging for storage until use is required.
  • Page 18: Usage

    Invacare® Platinum® Oxygen Concentrator 6 Usage WARNING! Risk of Injury or Damage To avoid injury or damage from airborne 6.1 Introduction pollutants and/or fumes and for optimal performance: Your oxygen concentrator is intended for individual use – Locate and position the concentrator in a well indoors.
  • Page 19: Setting Up The Concentrator

    Usage You may select a room in your house where using your 6.3.1 Setting Up the Humidifier (If Prescribed) oxygen concentrator would be most convenient. Your WARNING! concentrator can be easily rolled from room to room on Risk of Injury or Damage its casters.
  • Page 20 Invacare® Platinum® Oxygen Concentrator 3. Insert a flathead screwdriver in the plate groove C on Humidifier Bottle Humidifier Bottle without Cap the top edge of the filter access door D and gently pry with Cap the filter access door off.
  • Page 21 Usage 5. Attach the humidifier bottle adapter E to the humidifier 6. When placing the humidifier bottle in the compartment bottle B by turning the wing nut G on the humidifier F on the concentrator, attach the humidifier bottle counterclockwise until it is securely fastened. bottle/adapter tube H to the oxygen outlet connector I on the concentrator.
  • Page 22: Connecting/Positioning The Nasal Cannula

    Invacare® Platinum® Oxygen Concentrator 6.3.2 Connecting/Positioning the Nasal Cannula WARNING! Risk of Injury or Death DANGER! To reduce the risk of injury or death from illness: Risk of Injury or Death – Replace the nasal cannula on a regular basis.
  • Page 23 Usage Fig. 6-2 Concentrator with Humidifier Fig. 6-1 Concentrator without Humidifier 1. Remove the cannula from its packaging. 3. Perform one of the following: 2. Place the cannula A over your ears and position the • For use with a humidifier bottle—Attach the prongs in your nose as instructed by your health care patient’s nasal cannula supply tube B to the provider or cannula manufacturer.
  • Page 24: Turning The Concentrator On

    Invacare® Platinum® Oxygen Concentrator 6.3.3 Turning the Concentrator On Gas flow at the outlet of the cannula can be checked while the concentrator is warming up. Wave your hand in front of the nasal prongs. You should be able to hear and feel the flow of gas. If you do not feel the gas , check the cannula connection for leaks.
  • Page 25: Flowrate

    Usage 6.3.4 Flowrate 1. Turn the flowrate knob A to the setting prescribed by your physician or therapist. WARNING! To properly read the flowmeter B, locate the Risk of Minor Injury or Discomfort prescribed flowrate line on the flowmeter. Next, It is very important to select the prescribed turn the flow knob until the ball C rises to the oxygen flow setting.
  • Page 26: Senso Oxygen Purity Indicator

    Invacare® Platinum® Oxygen Concentrator 6.3.5 SensO Oxygen Purity Indicator 6.3.7 Explanation of Oxygen Purity Indicator Lights This feature monitors the purity of oxygen generated by the oxygen concentrator. If purity falls below factory preset standards, indicator lights on the control panel will illuminate.
  • Page 27: Elapsed Time Meter (Hour Meter)

    Usage Indicator Explanation Symbol Light Purity (LED) Immediately GREEN call supplier. light with Oxygen sensor YELLOW is malfunctioning. known light You may continue flashing to use the concentrator. Continuous Audible Alarm Sieve-GARD™ Compressor SYSTEM Shutdown FAILURE RED light SYSTEM FAILURE. (Solid) below Total unit...
  • Page 28: Maintenance

    – DO NOT hose down the product. DANGER! CAUTION! Risk of Injury or Damage Risk of Damage Invacare oxygen concentrators are specifically Harsh chemical agents can damage the designed to minimize routine preventive concentrator. To avoid damage: maintenance. To prevent injury or damage: –...
  • Page 29: Cleaning The Cabinet Filter

    Maintenance Periodically clean the concentrator’s cabinet as follows: 1. Use a damp cloth or sponge with a mild detergent, such as Dawn dish washing soap, to gently clean the exterior case. 2. Allow the concentrator to air dry or use a dry towel before operating the concentrator.
  • Page 30 Invacare® Platinum® Oxygen Concentrator 1. Remove the filter A and clean as needed. Environmental conditions that may require more frequent inspection and cleaning of the filter include, but are not limited to: high dust, air pollutants, etc. 2. Clean the cabinet filter with a vacuum cleaner or wash with a mild liquid dish detergent (such as Dawn) and water.
  • Page 31: Humidifier Cleaning And Thermic Disinfection

    Maintenance 7.4 Humidifier Cleaning and Thermic Disinfection 1. Dispose of and replace all patient side accessories not suitable for multiple patient use, including but not Clean and disinfect the oxygen humidifier daily to limited to: reduce limestone deposits and eliminate possible •...
  • Page 32: Preventive Maintenance Checklist

    Invacare® Platinum® Oxygen Concentrator 7.6 Preventive Maintenance Checklist ON EACH INSPECTION Record Date of Service Record Elapsed Hours on Hour Meter Clean Cabinet Filter(s) (Refer to Cleaning the Cabinet Filter.) Check Prescribed L/min Flowrate DURING PREVENTIVE MAINTENANCE SCHEDULE, OR BETWEEN PATIENTS...
  • Page 33: After Use

    After Use 8.2 Wear and Tear 8 After Use Invacare reserves the right to ask for any item back that 8.1 Recycling Information has an alleged defect in workmanship. See Warranty that shipped with the product for specific warranty information.
  • Page 34: Troubleshooting

    Invacare® Platinum® Oxygen Concentrator 9 Troubleshooting 9.1 Troubleshooting SYMPTOM PROBABLE CAUSE SOLUTION Alarm: Main Power Loss: No lights illuminated or lights 1. Power cord not plugged in. 1. Insert plug into outlet. flashing intermittently. 2. No power at outlet. 2. Inspect house circuit breakers or fuses. If problem 3.
  • Page 35 Troubleshooting SYMPTOM PROBABLE CAUSE SOLUTION Alarm: Potential Obstruction Alert GREEN light illuminated. 1. Possible internal obstruction 1. Inspect for kinks or blockages. Correct, clean or in the oxygen path. Kinked replace item. Once corrected, turn power Off for 60 Rapid or blocked tubing, cannula or seconds and then turn power back On.
  • Page 36: Technical Data

    Invacare® Platinum® Oxygen Concentrator 10 Technical Data 10.1 Specifications Electrical Requirements: 230 VAC +10, -15% (253 VAC/195.5 VAC), 50 Hz Rated Current Input: 2.3 A Sound Pressure Level: < 50 dBA weighted for 3 L/min flow < 50 dBA weighted for 9 L/min flow Sound Power Level: <...
  • Page 37 Technical Data Pressure Relief Mechanism 241 kPa ± 34.5 kPa (35 psi ± 5 psi) Operational at: Change in maximum recommended 0.7 L/min flow when back pressure of 7 kPa is applied: Filters: Cabinet (2), Outlet HEPA and Compressor Inlet Safety System: Current overload or line surge shutdown.
  • Page 38 Invacare® Platinum® Oxygen Concentrator Standards and Regulatory Listing: Certified complying with: IEC/EN 60601-1 IEC/EN 60601-1-2 IEC/EN 60601-1-6 IEC/EN 60601-1-11 ISO 80601-2-69 IRC9LXO2AWQ CE marked model: Electrical: No extension cords. Placement: No closer than 30.5 cm (12 in) from any wall, furniture, draperies or similar surfaces to assure sufficient air flow.
  • Page 39: Electromagnetic Compliance (Emc)

    Technical Data 10.2 Electromagnetic Compliance (EMC) Guidance and manufacturer´s declaration—electromagnetic emission The Device is intended for use in the electromagnetic environment specified below. The customer or the user of the Device should assure that it is used in such an environment. Emissions test Compliance Electromagnetic environment - guidance...
  • Page 40 Invacare® Platinum® Oxygen Concentrator Electrical Fast Mains power quality should be that of a typical transient / burst ± 2 kV mains, 100kHz ± 2 kV mains, 100kHz commercial or hospital environment. IEC 61000-4-4 Surge ± 1 kV line(s) to line(s) ±...
  • Page 41 Technical Data Portable and mobile RF communications equipment should be used no closer to any part of the Device including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter. Recommended separation distance: Conducted RF 3 Vrms, 6 Vrms 3 Vrms, 6 Vrms...
  • Page 42 Invacare® Platinum® Oxygen Concentrator measured field strength in the location in which the Device is used exceeds the applicable RF compliance level above, the Device should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the Device.
  • Page 43 Technical Data For transmitters rated at a maximum output power not listed above the recommended separation, distance d in meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.
  • Page 44: Warranty

    Terms and conditions of the warranty are part of the general terms and conditions particular to the individual countries in which this product is sold. Belgium & Luxemburg: Invacare nv, Autobaan 22, B-8210 Loppem • Tel: (32) (0) 50 83 10 10 • Fax: (32) (0) 50 83 10 11 • belgium@invacare.com • www.invacare.be Danmark: Invacare A/S, Sdr.
  • Page 45 Camp Mobility • Patamäenkatu 5, 33900 Tampere • Tel: 09-350 76 310 • info@campmobility.fi • www.campmobility.fi Invacare AG • Benkenstrasse 260 • CH-4108 Witterswil • Tel.: (41) (0)61 487 70 80 • Fax.: (41) Schweiz/Suisse/Svizzera: (0)61 487 70 81 • switzerland@invacare.com • www.invacare.ch United Kingdom: Invacare Limited, Pencoed Technology Park, Pencoed, Bridgend CF35 5HZ •...
  • Page 46 Notes...
  • Page 47 Notes...
  • Page 48 Invacare Corporation Manufacturer One Invacare Way Invacare Corporation Elyria, Ohio 44035 2101 E. Lake Mary Blvd. United States Sanford, FL 32773 Tel: 440–329–6000 United States Tel: 800–333–6900 Tel: 407–321–5630 Technical Services Tel: 440–329–6593 Tel: 800–832–4707 www.invacare.com EU Representative Invacare Deutschland GmbH Kleiststraße 49...

Table of Contents