Downflow air discharge
Table of Contents

Advertisement

TABLE 2
COMBUSTIBLE FLOORING BASE OPENING SIZE
Front to Rear
Cabinet
Catalog
Width
Number
in
B (17.5")
11M60
22
C (21")
11M61
22
FURNACE
PROPERLY
SIZED FLOOR
OPENING
FIGURE 15
2 - After opening is cut, set the combustible flooring
base into opening.
3 - Check fiberglass strips on the combustible flooring
base to make sure they are properly glued and
positioned.
4 - Lower supply air plenum into the combustible flooring
base until plenum flanges seal against fiberglass
strips.
NOTE - Be careful not to damage fiberglass strips.
Check for a tight seal.
5 - Set the furnace over the plenum.
6 - Ensure that the seal between the furnace and
plenumis adequate.
Installation on Cooling Coil Cabinet FIGURE 16
NOTE - Downflow combustible flooring kit is not used.
1 - Refer to reverse-flow coil installation instructions for
correctly sized opening in floor and installation of
cabinet.
2 - When cooling cabinet is in place, set and secure
the furnace according to the instructions that are
provided with the cooling coil. Secure the furnace to
the cabinet.
3 - Seal the cabinet and check for air leaks.
Side to Side
mm
in
mm
559
18-3/4
476
559
22-3/4
578
SUPPLY AIR
PLENUM
COMBUSTIBLE
FLOORING BASE
PROPERLY
SIZED FLOOR
OPENING
Return Air Opening -- Downflow Units
Return air may be brought in only through the top opening
of a furnace installed in the downflow position. The follow-
ing steps should be taken when installing plenum:
1 - Bottom edge of plenum should be flanged with a
hemmed edge (See FIGURE 17 or FIGURE 18).
2 - Sealing strips should be used to ensure an airtight
seal between the cabinet and the plenum.
3 - In all cases, plenum should be secured to top of
furnace using sheet metal screws.
4 - Make certain that an adequate seal is made.
PLENUM
(Field Provided)
SEALING STRIP
(Field Provided)
PLENUM
(Field Provided)
SECURE FROM
INSIDE CABINET
Page 11
FURNACE
COOLING COIL
PLENUM
FIGURE 16
SECURE FROM
OUTSIDE CABINET
CABINET
SIDE PANEL
Side View
FIGURE 17
SEALING STRIP
(Field Provided)
CABINET
SIDE PANEL
Side View
FIGURE 18