Modify the SAN I/O Module IP address

Modify the SAN I/O Module IP address
By default, the IP address for the SAN I/O Module is configured as 10.77.77.77 with a default
Ethernet subnetmask of 255.255.255.0.
Reset the IP address using three methods. If the IP values are set using either of these methods,
the IP values are stored on the SAN I/O Module.
ATTENTION
Do not connect the SAN I/O Module to the internal network until the IP address is correctly set for
your Ethernet network requirements.
NOTE
It is recommended that you set the IP address using the Blade Server Enclosure CMC GUI
application because this enables centralized management of the SAN I/O Module.

Using the SAN I/O Module CLI to set the IP address

Use the following tasks to change the IP address on the SAN I/O Module using the Module's CLI.
Task 1: Establish a terminal session with the SAN I/O Module
Use these steps to establish a terminal emulation session between the SAN I/O Module and a
Blade Server Enclosure management workstation used for managing the I/O Module. Once this
session is established, you can log into the Module and use its CLI commands to manage the
module.
1. Connect a serial cable between the serial console port on the SAN I/O Module and a Blade
2. Disable any serial communication programs that are running on the workstation.
3. Using a terminal emulator application (such as HyperTerminal on a PC or TERM in a LINUX or
For Windows 95, 98, 2000, XP or NT
10
Access Gateway Administrator's Guide
Web Tools Administrator's Guide
SAN I/O Module Command Line Interface (CLI).
Blade Server Enclosure CMC CLI.
Blade Server Enclosure CMC graphical user interface (GUI).
Server Enclosure management workstation that can establish a terminal emulation session
with the SAN I/O Module. For instructions, refer to Configuration Guide for your Blade Server
enclosure.
UNIX environment), establish a terminal session to the SAN I/O Module from the management
workstation. You will use this connection if you want to reset the module's IP address using CLI
commands and perform other configuration tasks.
a. Click Start and select Programs -> Accessories -> Communications.
b. Select Hyperterminal and enter a name for the connection.
4424 Blade Server SAN I/O Module Hardware Reference Manual
53-0000571-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Poweredge m420Poweredge m5204424

Table of Contents