Frico AREC3200C Original Instructions Manual

Hide thumbs Also See for AREC3200C:

Advertisement

Quick Links

Original instructions
AREC3200C
EN
FR
.... 17
.... 23
Frico AB certifies that the AREC3200CA, AREC3200CE and AREC3200CW air curtains shown herein
are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures
performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply
with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal
applies to airflow rate, average outlet velocity, outlet velocity uniformity, velocity projection and
power rating at free delivery only.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AREC3200C and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Frico AREC3200C

  • Page 1 ..17 ..23 Frico AB certifies that the AREC3200CA, AREC3200CE and AREC3200CW air curtains shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.
  • Page 2: Metric Chart

    10.97 9.50 Frico AB certifies that the AREC3200CA, AREC3200CE and AREC3200CW air curtains shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.
  • Page 3: Imperial Chart

    2159 1870 Frico AB certifies that the AREC3200CA, AREC3200CE and AREC3200CW air curtains shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.
  • Page 4 AREC3200C Output charts water AREC3200C Metric chart Supply water temperature:80 °C Water temperature: 80/60 °C Room temperature: +18 °C Room temperature: +18 °C Outlet air temperature: +35 °C* Type Airflow Output Return Water Pressure Output* Outlet Water Pressure position water temp.
  • Page 5 AREC3200C The introduction pages consist mainly of pictures. For translation of the English texts used, see the respective language pages. Les pages de présentation contiennent principalement des images. Pour la traduction des textes en anglais, consultez la page correspondante à la langue...
  • Page 6 AREC3200C Metric Imperial 1, 1,5 m: 4 x M8 1 m: 4 x M8 3.3 ft: 4 x M8 2 m: 6 x M8 1.5 m: 4 x M8 4.9 ft: 4 x M8 2 m: 6 x M8 6.6 ft:...
  • Page 7: Side View

    AREC3200C Mounting on threaded bars outside the unit Front view AREC3210Cx/AREC3215Cx Side view 805 / 1315 A / B AREC3220Cx Metric Imperial Product type [mm] [in] 32.20 AREC3210Cx 1315 52.60 AREC3215Cx 2.64 6.28 37.32 32.20 5.36 6.24 21.00 9.76...
  • Page 8 AREC3200C Mounting on threaded bars outside the unit Fig. 1a: Mounting brackets on delivery. AREC3220Cx Fig. 1b. Mounting on threaded bars outside the unit.
  • Page 9 E/A: 851 W: 935 AREC3200C Mounting on threaded bars inside the unit Top view AREC3210Cx/ AREC3215Cx 850 / 1360 A / B Side view AREC3220Cx E/A: 851 E/A: 932 W: 935 W: 848 Metric Imperial Product type [mm] [in] 34.00...
  • Page 10 AREC3200C Mounting on threaded bars inside the unit AREC3220Cx Fig. 2b. Mounting on threaded bars inside the unit. AREC3210Cx, AREC3215Cx 4x AREC3220Cx 6x Fig. 2c. Location of the mounting brackets on the inside of the unit. Fig. 2d. In order to mount the brackets, remove the service hatch, outlet grille and covering plates.
  • Page 11 AREC3200C AREC 90° Service hatch Fig. 3a: Snap fixings Fig. 3b: Open the unit. Fig. 4: Terminal box and control panel inside unit.
  • Page 12 AREC3200C Accessories PA34TR15 AREC3210Cx, AREC3215Cx, 1 m/3.3 ft PA34TR20 AREC3220Cx, 1 m/3.3 ft PA34CB15 AREC3210Cx, AREC3215Cx PA34CB20 AREC3220Cx FHDN15 PA34VD15 AREC3210Cx, AREC3215Cx PA34VD20 AREC3220Cx PA34VD FHDN15 AREC3200CW PA34CB PA34TR Type Connection VLSP-NA VLSP15NF-NA DN15 VLSP20NF-NA DN20 Nipple SD230 BPV10 G-NPT...
  • Page 13 AREC3200C AREC3200CA/W 208V1~ L1 L2 5A x 3 Only 2 m version SENSOR 0 - 10V DOOR PE N 6 5 4 AFTER WATER Only water PE N 6 5 4 White / Tach Red / +10 V Yellow / 0-10...
  • Page 14 AREC3200C AREC3200CE-208V 0 -10V N H1H2 N F1 F2 F3 Yellow Blue White...
  • Page 15 AREC3200C AREC3200CE-480V/600V 0 - 10V N H1H2 N F1 F2 F3 Yellow Blue White...
  • Page 16 AREC3200C • Read the safety instructions before performing installation and/or maintenance activities on the unit. • Installation and/or maintenance activities on the unit may only be performed by qualified technical staff. • The unit shall not be installed and used outdoors or in environments that are aggressive, or potentially explosive.
  • Page 17: General Instructions

    AREC3200C is a compact air curtain for recessed For the protection of wider doorways, several mounting. The air curtain is available without...
  • Page 18: Control Options

    Note that the unit shall be preceded by a fixings lock securely. regulating valve, see Frico valve kit.
  • Page 19: Maintenance

    AREC3200C Maintenance Temperature control Unit with water heating See control pages. The appliance filter should be cleaned regularly to ensure the air curtain effect and heat Replacing motor or impeller emission from the device. How often depends 1. Remove frame and side panel.
  • Page 20: Troubleshooting

    AREC3200C Troubleshooting Handling of product at end of working If the fans are not running or do not perform pro- life perly, check the following: This product may contain substances necessary • The functions and settings of the built-in for the functionality of the product but potentially dangerous for the environment.
  • Page 21 AREC3200C Control The control system is integrated in the air curtain. The air curtain can be regulated with a remote control or by the control panel placed inside the service hatch. 208V~ Black Actuator SD230 (remove the quick Brown connector)
  • Page 22: Functional Test

    AREC3200C Fan step 1/2/3 ~20 °C Heat step Electric: Half/full power Water: On/off (1 LED) On/off Control panel - Unit with electrical heating or water heating Fan step 1/2/3 On/off Control panel - Unit without heating Remote control - on/off, fan steps and heating steps...
  • Page 23 Main offi ce Frico AB Tel: +46 31 336 86 00 Industrivägen 41 SE-433 61 Sävedalen mailbox@frico.se Sweden www.frico.net For latest updated information and information about your local contact: www.frico.se...

Table of Contents