Arden 3500 The introduction pages consist mainly of pictures. For translation of the English texts used, see the respective language pages. Introduktionssidorna består huvudsakligen av bilder. För översättning av de engelska texter som används, se respektive språksidor. Introduksjonssidene består hovedsakelig av bilder. For oversettelse av de engelske tekstene, se de respektive språksidene...
Page 4
Arden 3500 Mounting Fig. 1a: Mounting brackets on delivery. Fig. 1b: Mounting on threaded bars outside the unit. Fig. 2: Mounting on threaded bars inside the unit. Note that the brackets are placed at different heights and therefore threaded rods should be of different lengths.
Arden 3500 Service hatch 90° Service hatch Fig. 3: Snap fixings Gland PC board FC Fig. 4: PC board FC is integrated within the air curtain at delivery. Water connections DN20 (3/4’’), inside thread Fig. 5: The water coil is connected inside the unit through holes which are made (during installation)
Arden 3500 Control systems The air curtain must be supplemented with a control system. FCDA - FC Direct FCSA - FC Smart FCCF FCDC FCBC10 FCLAP FCCF FCDC FCBC05 FCPA - FC Pro FCBA - FC Building FCCF FCDC FCBC10...
Page 8
Arden 3500 ARFEC3500 A 3510: 2 Motors 4210/5010: 3 Motors 3515: 3 Motors 4215/5015: 4 Motors 3520: 4 Motors 4220/5020: 6 Motors 3525: 5 Motors 4225/5025: 7 Motors +12V +12V FCBASE REA Trafo PAFEC/ARFEC 3500 A PAFEC/ARFEC 4200 A PAFEC/ARFEC 5000 A 230V~ Wiring diagrams for control system in the FC manual.
Page 9
Arden 3500 ARFEC3510/3515 E 3510: 2 Motors 4210/5010: 3 Motors 3515: 3 Motors 4215/5015: 4 Motors Inlet sensor Outlet sensor +12V +12V FCBASEPCB REA Trafo PAFEC/ARF PAFEC/ARF PAFEC/ARF 230V~ 400V 3~ Wiring diagrams for control system in the FC manual.
Page 10
Arden 3500 ARFEC3520 E 3520: 4 Motors Inlet sensor Outlet sensor +12V +12V FCBASEPCB REA Trafo ARFEC3520E 317535 400V 3~ 230V~ Wiring diagrams for control system in the FC manual.
) ∆t = temperature rise of passing air at maximum heat output and low/high airflow (2/10V). ) Applicable at water temperature 60/40 °C, air temperature, in +18 °C. ) Applicable at water temperature 40/30 °C, air temperature, in +18 °C. ) See www.frico.net for additional calculations.
Lock using the upper nut. Application Arden 3500 is an air curtain for recessed Mounting on threaded bars inside the unit mounting. Recommended installation height 1. The mounting brackets are fixed to the 3,5 m.
Note that the unit shall be preceded by a snap fixings lock securely. regulating valve, see Frico valve kit. To access the connections the service hatch Maintenance and intake grille must be opened. The...
Arden 3500 Temperature control motor’s operating limits. Failure or damage to electronics components may require repair or Temperature control of FC maintains the replacement of such components or the entire exhaust temperature. Should the temperature product. exceed the preset value, the overheating alarm will activate.
Page 16
Arden 3500 Safety Residual current circuit breaker (E) • For all installations of electrically heated When the installation is protected by means of a residual current circuit breaker, which trips products a residual current circuit breaker when the appliance is connected, this may be 300 mA for fire protection should be used.
Page 18
Main offi ce Frico AB Tel: +46 31 336 86 00 Industrivägen 41 SE-433 61 Sävedalen mailbox@frico.se Sweden www.frico.net For latest updated information and information about your local contact: www.frico.net.