5.1 Replacing the O-ring in the valves of X series

5
· Remove the handle or control knop by pulling
hard on it directly upwards
· Remove the retaining ring
· Remove the stem sealing bush
· Remove the damaged O-ring
· Put the new O-ring in place by pressing the
upper surface evenly downwards
Component
1 Retaining ring
2 Stem sealing bush
3 O-ring
4 Handle
5 Precision control knop
www.vexve.com
2
Steel
Stainless steel
299415
901088
901105
901115
901130T
1
3
· Put the new stem sealing bush in place by
pressing the upper surface evenly downwards
· Put the new retaining ring in place
· Put the removed handle or control knop back
in place
289115
901088
901101
901115
901130H
4