INSTALLATION
Perform the following operations in sequence:
configure jumpers J11, J12 and LAUNCHING according to siren starting mode.
connect the 12VDC 2Ah buffer battery to the red and black wires with faston (in case of "launching"
starting mode, there is no battery);
connect external 13.8 VDC power supply to the SUPPLY terminals (*);
connect siren start line from the alarm panel to the START terminal (in case of "launching" starting
mode, the START terminal must be connected to the +12V terminal);
the anti-opening/tearing contact must be connected to the relevant circuit of the alarm unit through the
TAMPER contacts;
time the trimmer to desired sound and flash;
close the metal cover using the screws provided
close the siren by means of the plastic cover.
FRANÇAIS
Sirène extérieure auto-alimentée
Auto-protection et à l'ouverture à l'arrachement
Durée du flash et du son réglable de 1' à 7'
CONFIGURATION
COMMANDE PAR + DE BLOCAGE
COMMANDE PAR - DE BLOCCAGE
COMMANDE PAR APPARITION DE TENSION
Dans le cas d'une utilisation avec la commande à apparition de tension ne pas connecter la batterie sur les bornes + et - 12 v
t 1 + potentiometre de reglage du temps de travail de 1 à 7 mn
Tourner T1 dans le sens des aiguilles d'une montre pour augmenter le temps de travail
Caractéristiques techniques
Alimentation :
Alimentation limite de fonctionnement :
Consommation maxi en fonctionnement :
Consommation en veille :
IP
J 11 OUVERT
J 12 SUR B
LAUNCHING SUR OFF
J 11 FERME
J 12 SUR A
LAUNCHING SUR OFF
J 11 OUVERT
J 12 SUR A
LAUNCHING SUR ON
13,8 Vcc Puissance sonore (aVn=12Vcc) : 110dB(A) à 3 m
10 +/- 15 Vcc Puissance lumineuse : 10W
1,5 A Batterie en tampon : 2Ah
2.5mA Dimensions mm : L 236 x H 280 x P 99