5] WIRING SCHEMATIC

Example N°1: Exit button only (VHLD timer optional)
Voltage 12Vdc
or 24Vdc
Time relay for magnetic locks (Ref: TPV)
Important: When using a timer in circuit, please
make note of the voltage used and ensure the
timer can operate at the same voltage
(example shows TPV)
Adjustable timer
(0 to 20 seconds)
Example N°2: Access Control + Exit Button
Access
Control
Unit
Voltage 12Vdc
or 24Vdc
Exit
Button
Exit
Button
BO600RH RANGE
Electromagnetic lock
300KG
Electromagnetic lock
300KG
5-Way Terminal Strip –
monitored version
+
12Vdc or 24Vdc positive *
-
12Vdc or 24Vdc negative *
NC
Contact «Normally Closed»
COM Common
NO
Contact «Normally Open»
* Voltage: 12Vdc or 24Vdc.
Place the « jumpers » to select 12Vdc
or 24Vdc supply to your magnetic locks.
BO600RH RANGE
Electromagnetic lock
300KG
Electromagnetic lock
300KG
EN
12Vdc
24Vdc
5-Way Terminal Strip
– non monitored version
+ 12Vdc or 24Vdc positive *
- 12Vdc or 24Vdc negative *
* Voltage: 12Vdc or 24Vdc.
Place the « jumpers » to select
12Vdc or 24Vdc supply to your
magnetic locks
12Vdc
24Vdc
12Vdc
24 Vdc
5-Way Terminal Strip
– non monitored version
+ 12Vdc or 24Vdc positive *
- 12Vdc or 24Vdc negative *
* Voltage: 12Vdc or 24Vdc.
Place the « jumpers » to select
12Vdc or 24Vdc supply to your
magnetic locks.
cdvi.com
cdvigroup.com
5