Serial Command - Omega IF-006 User Manual

Layer n wireless universal smart interface
Table of Contents

Advertisement

8.9

Serial Command

The Serial command allows setting specific operating characteristics of the Serial (USB) interface. If no option is
provided the current settings for the selected characteristic are provided.
S(erial) <B(audrate) = 9600 | 19200 | 38400 | 115200> <P(arity) = E(ven) | O(dd) | M(ark) | N(one)>
<S(top) = 0 | 1> <D(ata) = 7 | 8> <R(eset)>
S
Baudrate = 115200, Parity = Even, Data = 8, Stop = 1
Multiple options may be set on the same command line in any order. The updated configuration will be shown
using the current serial configuration and then all changes are applied at once.
Serial BR=38400, Stop = 1, Data=7 Parity = Odd
Baudrate = 38400, Parity = Odd, Data = 7, Stop = 1
<changes are applied, terminal configuration must be changed to match new configuration>
Characteristic
Baudrate
Parity
Stop
Data
Reset
Options
9600, 19200, 38400, 115200
Even, Odd, Mark, None
1, 2
7, 8
--
Usage
Serial Baudrate = 38400
S P=None
S S=2
Serial Databits = 8
Resets serial configuration to 115200,
Even, 8, 1
37 |
P a g e