Alarmzone 1 And 2 - Renkforce 752168 Operating Instructions Manual

2-zone alarm device
Table of Contents

Advertisement

Available languages

Available languages

7.1 Alarmzone 1 and 2

Notes:
N.O (Normally open - contacts, sensors with open contacts - closed
in case of alarm)
N.C (Normally closed - contacts, sensors with closed contacts - open
in case of alarm)
In both alarm zones, sensors with N.C. and N.O. contacts can be
used.
Alarm zone 1 triggers the alarm immediately in case of alarm.
Connection example
alarm zone 1:
Alarm zone 2 triggers the alarm with a delay after the end of the entry delay (=
30 seconds).
Connection example
alarm zone 2:
Alarm zone 1 corresponds to terminal clamps 1 and 2.
Alarm zone 2 corresponds to terminal clamps 2 and 3.
36