4. Specifications
4.1 Driver Specifications
Type
Drive Method
Input Voltage
Operate
Temp.
Reserve
Operate
Humidity
Reserve
Vib. Resist.
Resolution(P/R)
May. Freq.
Alarm Function
LED Display
STOP Current
Pulse Input Method
Rotational Dir.
Speed/Position
Commamd
Input Signals
I/O
Output Signals
EzStep-BT-42-S/M/L
Bipolar PWM drive with 32bit DSP
24 VDC ±10%
0 ~ +50℃
-20 ~ +70 ℃
35~85% RH (Non condensing)
10~90% RH (Non condensing)
0.5G
500, 1000, 1600, 2000, 3200, 3600, 4000, 5000, 6400, 8000,
10000, 20000, 25000,36000, 40000, 50000 (Set by RS232C
Communication)
*Default : 10000
500 KHz (Duty 50%)
Step-Out, Over-Current, Over-Heat, Over-Voltage
Power Status(Green), Alarm Status(Red)
10% ~ 100% (Set by RS-232C Communication)
Be setted to set value of STOP current after 0.5 second after motor
stop.
*Default : 50%
1 Pulse / 2 Pulse (Set by RS-232C Communication)
1 Pulse: Pulse / Direction, 2 Pulse: CW / CCW
*Default : 2 pulse
CW / CCW (Set by RS232C Communication)*Default : CW
Used when changing the direction of motor rotate.
*Default : CW
Pulse train input (Photocoupler Input)
Photocoupler Input : Motor Free, Alarm Reset
Photocoupler Output : Alarm, Run/Stop
EzStep-BT-56-S/M/L/XL