Technical data

Table 6- 1
Product type designation
Transmission speed
Maximum transmission speed
on point-to-point connections (serial)
Interfaces
Design of the interface for
point-to-point connection
Max. cable length
Number of connectable readers
Electrical connection version
Version of the interface (to the reader)
Max. block length
Electrical data
Supply voltage
Current consumption
Galvanic isolation
SIMATIC RF120C
Operating Instructions, 02/2021, C79000-G8976-C328-03
Technical specifications of the RF120C
of the backplane bus
For supply voltage
1)
Rated value
Permissible range
via backplane bus
from ext. power supply, without devices
connected
from ext. power supply, including connect-
ed devices
2)
SIMATIC RF120C
115.2 Kbps
RS422, RS232
RS422: 1000 m, reader-dependent
RS232: 15 m
1
S7-1200 backplane bus
Screw terminals
9-pin D-sub female
1 word cyclic / 240 bytes acyclic
24 V DC
20 to 30 VDC
typically 110 mA; max. 250 mA
typically 30 mA
max. 1 A
Yes