3. Are you getting electricity from the wall outlet? Check by plugging in another piece of
equipment with the same electrical requirements. Also, check circuit breaker or fuse.
4. If you are getting electrical power and your slicer is still not operating, contact your Berkel
serviceman.
Thickness control knob not operating gauge plate
1. If the thickness control knob is not opening and closing the gauge plate properly, it is a sign
that the internal mechanism has suffered some loss of adjustment. Do not try to adjust the
mechanism yourself. Call your Berkel Serviceman.
Not able to remove the product table
1. Is the index knob completely closed and is the table in the home, or most forward position?
Table not moving (839A)
1. Is the manual/automatic knob turned fully clockwise? If yes, then the drive mechanism is
in need of repair. Call you nearest Berkel Serviceman.
If correction of any of the above conditions does not result in a functional slicer, call your
Designated Berkel Service Location.
Please contact your Designated Berkel Service Location for any repair parts and/or repair
service required on your Berkel slicer. Additional information may be obtained from:
Service Support Center
Berkel Company
4406 Technology Drive
South Bend, Indiana 46628-9700
574/232-8222 · Fax 888-888-2838
(800)348-0251
12 • 829A & 839A O
WNER
R
P
EPAIR
ARTS
/O
M
L
PERATOR
ANUA
/R
S
EPAIR
ERVICE

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

839a

Table of Contents